SC-15(1) Physical or Logical Disconnect
Enhancement of: SC-15
High-Level Description
Family: System and Communications Protection (SC) Framework: NIST SP 800-53 Rev 5
Failing to disconnect from collaborative computing devices can result in subsequent compromises of organizational information. Providing easy methods to disconnect from such devices after a collaborative computing session ensures that participants carry out the disconnect activity without having to go through complex and tedious procedures. Disconnect from collaborative computing devices can be manual or automatic.
What to Check
- Verify SC-15(1) Physical or Logical Disconnect is documented in SSP
- Confirm control is operating effectively
- Review evidence of continuous monitoring for SC-15(1)
- Verify enhancement builds upon base control SC-15
How to Test
Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-15(1) implementation details. Verify the organization has documented how this control is satisfied.
Step 2: Validate Implementation
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
Tools
| Tool | Purpose | Usage |
|---|---|---|
| cloud-audit-mcp | Check encryption and network controls | cloud_audit_encryption |
| nmap | Network scanning | nmap -sV --script ssl-enum-ciphers |
Remediation Guide
Control Statement
Provide [organization-defined] disconnect of collaborative computing devices in a manner that supports ease of use.
Implementation Guidance
Failing to disconnect from collaborative computing devices can result in subsequent compromises of organizational information. Providing easy methods to disconnect from such devices after a collaborative computing session ensures that participants carry out the disconnect activity without having to go through complex and tedious procedures. Disconnect from collaborative computing devices can be manual or automatic.
Risk Assessment
| Finding | Severity | Impact |
|---|---|---|
| SC-15(1) Physical or Logical Disconnect not implemented | High | System and Communications Protection |
| SC-15(1) partially implemented | Medium | Incomplete System and Communications Protection |
CWE Categories
| CWE ID | Title |
|---|---|
| CWE-311 | Missing Encryption of Sensitive Data |
References
- NIST SP 800-53 Rev 5 - SC-15(1)
- NIST SP 800-53A Rev 5 (Assessment Procedures)
- NIST SP 800-53 Rev 5 Full Catalog
Checklist
- Control documented in SSP
- Implementation evidence collected
- Operating effectiveness validated
- Continuous monitoring in place
- Related controls (none) reviewed