SC-37 Out-of-band Channels
High-Level Description
Family: System and Communications Protection (SC) Framework: NIST SP 800-53 Rev 5
Out-of-band channels include local, non-network accesses to systems; network paths physically separate from network paths used for operational traffic; or non-electronic paths, such as the U.S. Postal Service. The use of out-of-band channels is contrasted with the use of in-band channels (i.e., the same channels) that carry routine operational traffic. Out-of-band channels do not have the same vulnerability or exposure as in-band channels. Therefore, the confidentiality, integrity, or availability compromises of in-band channels will not compromise or adversely affect the out-of-band channels. Organizations may employ out-of-band channels in the delivery or transmission of organizational items, including authenticators and credentials; cryptographic key management information; system and data backups; configuration management changes for hardware, firmware, or software; security updates; maintenance information; and malicious code protection updates. For example, cryptographic keys for encrypted files are delivered using a different channel than the file.
What to Check
- Verify SC-37 Out-of-band Channels is documented in SSP
- Confirm control is operating effectively
- Review evidence of continuous monitoring for SC-37
How to Test
Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for SC-37 implementation details. Verify the organization has documented how this control is satisfied.
Step 2: Validate Implementation
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
Tools
| Tool | Purpose | Usage |
|---|---|---|
| cloud-audit-mcp | Check encryption and network controls | cloud_audit_encryption |
| nmap | Network scanning | nmap -sV --script ssl-enum-ciphers |
Remediation Guide
Control Statement
Employ the following out-of-band channels for the physical delivery or electronic transmission of [organization-defined] to [organization-defined]: [organization-defined].
Implementation Guidance
Out-of-band channels include local, non-network accesses to systems; network paths physically separate from network paths used for operational traffic; or non-electronic paths, such as the U.S. Postal Service. The use of out-of-band channels is contrasted with the use of in-band channels (i.e., the same channels) that carry routine operational traffic. Out-of-band channels do not have the same vulnerability or exposure as in-band channels. Therefore, the confidentiality, integrity, or availability compromises of in-band channels will not compromise or adversely affect the out-of-band channels. Organizations may employ out-of-band channels in the delivery or transmission of organizational items, including authenticators and credentials; cryptographic key management information; system and data backups; configuration management changes for hardware, firmware, or software; security updates; maintenance information; and malicious code protection updates. For example, cryptographic keys for encrypted files are delivered using a different channel than the file.
Risk Assessment
| Finding | Severity | Impact |
|---|---|---|
| SC-37 Out-of-band Channels not implemented | High | System and Communications Protection |
| SC-37 partially implemented | Medium | Incomplete System and Communications Protection |
CWE Categories
| CWE ID | Title |
|---|---|
| CWE-311 | Missing Encryption of Sensitive Data |
References
- NIST SP 800-53 Rev 5 - SC-37
- NIST SP 800-53A Rev 5 (Assessment Procedures)
- NIST SP 800-53 Rev 5 Full Catalog
Checklist
- Control documented in SSP
- Implementation evidence collected
- Operating effectiveness validated
- Continuous monitoring in place
- Related controls (AC-2, CM-3, CM-5, CM-7, IA-2) reviewed