Advanced Control, MPC, and Virtual Sensing
When to use this
Use this skill when NeqSim's existing dynamic/process model needs a controller-facing model, bounded receding-horizon control, a physics-based soft measurement, or steady-state data reconciliation.
ProcessLinkedMPClinks configured manipulated, controlled, disturbance, and state variables to one existingProcessSystem; it identifies local dynamics and computes/apply moves.ProcessLinearizer,StepResponseGenerator,StateSpaceExporter,IndustrialMPCExporter, andSubrModlExportercreate model-identification and integration artifacts.ModelPredictiveControlleris a controller-device implementation with a first-order prediction model, constraints, feed-quality prediction, and optional moving-horizon estimation. It is not a DCS emulator.VirtualFlowMeterandSoftSensorestimate quantities/properties from a stream's fluid and supplied operating conditions. They are screening/model estimates, not custody-transfer instruments.SteadyStateDetectorandDataReconciliationEnginescreen input data and reconcile measured values against declared linear balance constraints.
Keep each layer distinct: dynamic simulation models process response (neqsim-dynamic-simulation); controllability/operability maps feasible envelopes (neqsim-controllability-operability); calibration and plant-data workflows select and qualify measurements (neqsim-model-calibration-and-data-reconciliation, neqsim-plant-data). Compressor minimum-speed/recycle coordination belongs to neqsim-compressor-antisurge-recycle.
Class map
| Class or family | Package | What it does | Key methods verified |
|---|---|---|---|
ProcessLinkedMPC |
neqsim.process.mpc |
Binds MVs/CVs/DVs/SVRs to a ProcessSystem, identifies its model and performs repeated control calculations. |
Constructor (String, ProcessSystem); addMV, addCV, addCVZone, addDV, addSVR, identifyModel, calculate, applyMoves, getLastMoves, getLinearizationResult, exportModel |
ProcessLinearizer, variable classes |
neqsim.process.mpc |
Computes local finite-difference gains for configured manipulated/controlled/disturbance variables. | ProcessLinearizer(ProcessSystem), addMV, addCV, addDV, linearize, setDefaultPerturbationSize |
StepResponseGenerator, StepResponse, NonlinearPredictor, derivative calculator |
neqsim.process.mpc |
Builds step-response models, finite-difference process responses, and optional nonlinear prediction inputs. | StepResponse constructor and response getters are documented in MPCIntegrationTest; verify a generator method before use |
| State-space and industrial exporters | neqsim.process.mpc |
Exports local linear model to discrete state-space, Industrial MPC, SubrModl, soft-sensor, and controller data-exchange formats. | StateSpaceExporter(LinearizationResult), toDiscreteStateSpace, getA, getB, getC, getD; createIndustrialExporter, createSubrModlExporter |
ModelPredictiveController |
neqsim.process.controllerdevice |
Standalone first-order, receding-horizon controller device with linear quality constraints and feed disturbance handling. | Constructors (), (String); setPredictionHorizon, setControllerSetPoint, setTransmitter, getResponse |
| Controller benchmarks and metrics/events | neqsim.process.controllerdevice |
Records controller benchmark scenarios, performance metrics, and events for comparative assessment. | APIs vary by object; inspect source before assuming metric units or benchmark acceptance |
| Logic/sequence/transfer-function blocks | neqsim.process.controllerdevice |
Provides logic blocks, sequential function charts, and transfer-function structures. | Use their public interfaces and transition/update APIs from source; these are not a plant DCS runtime |
| Cascade, feed-forward, override, ratio, split-range, minimum-speed recycle | neqsim.process.controllerdevice.structure |
Composes controller outputs for common multiloop, selector, and recycle-coordination patterns. | Minimum-speed integration is detailed in neqsim-compressor-antisurge-recycle |
VirtualFlowMeter, VFMResult, UncertaintyBounds |
neqsim.process.measurementdevice.vfm |
Estimates gas/oil/water rates and simple uncertainty bounds from stream fluid, pressure drop, choke opening, and calibration factor. | VirtualFlowMeter(String, StreamInterface), calculateFlowRates, setMeasurementUncertainties; getOilFlowRate, getGasFlowRate, getWaterFlowRate, getQuality, uncertainty getters |
SoftSensor |
neqsim.process.measurementdevice.vfm |
Estimates supported fluid properties by flashing a cloned stream fluid at supplied P/T. | SoftSensor(String, StreamInterface, PropertyType), setInput, setInputs, estimate |
SteadyStateDetector, SteadyStateVariable |
neqsim.process.util.reconciliation |
Tests incoming variable histories with a sliding-window steady-state detector before reconciliation/calibration. | SteadyStateDetector(int), addVariable, updateVariable, evaluate |
DataReconciliationEngine, ReconciliationVariable, ReconciliationResult |
neqsim.process.util.reconciliation |
Applies weighted least squares to measurement values under caller-defined linear equality balances; reports statistical flags. | addVariable, addConstraint(double[]), setGrossErrorThreshold, reconcile; isConverged, getErrorMessage, getVariables, getChiSquareStatistic, getGrossErrors |
Build pattern
The example starts from a converged separator/valve process. The local linear model and MPC operate around this configured point; they do not replace transient simulation or a validated control-system design.
import neqsim.process.mpc.ProcessLinkedMPC;
import neqsim.process.equipment.stream.Stream;
import neqsim.process.equipment.valve.ThrottlingValve;
import neqsim.process.equipment.separator.Separator;
import neqsim.process.processmodel.ProcessSystem;
import neqsim.thermo.system.SystemInterface;
import neqsim.thermo.system.SystemSrkEos;
SystemInterface fluid = new SystemSrkEos(298.15, 50.0);
fluid.addComponent("methane", 0.8);
fluid.addComponent("ethane", 0.1);
fluid.addComponent("propane", 0.05);
fluid.addComponent("n-pentane", 0.05);
fluid.setMixingRule("classic");
Stream feed = new Stream("feed", fluid);
feed.setFlowRate(100.0, "kg/hr");
feed.setTemperature(25.0, "C");
feed.setPressure(50.0, "bara");
ThrottlingValve valve = new ThrottlingValve("inlet_valve", feed);
valve.setOutletPressure(30.0);
Separator separator = new Separator("separator", valve.getOutletStream());
ProcessSystem process = new ProcessSystem();
process.add(feed);
process.add(valve);
process.add(separator);
process.run();
ProcessLinkedMPC mpc = new ProcessLinkedMPC("separator-pressure", process);
mpc.addMV("inlet_valve", "opening", 0.0, 1.0, 0.1);
mpc.addCV("separator", "pressure", 30.0);
mpc.setConstraint("separator", "pressure", 20.0, 40.0);
mpc.identifyModel(60.0);
mpc.setPredictionHorizon(20);
mpc.setControlHorizon(5);
double[] moves = mpc.calculate();
mpc.applyMoves();
Python exposes the same Java class lookup pattern. Use the shared NeqSim Python environment, and check whether the installed bridge requires Java overload disambiguation.
from neqsim import jneqsim
SystemSrkEos = jneqsim.thermo.system.SystemSrkEos
Stream = jneqsim.process.equipment.stream.Stream
ThrottlingValve = jneqsim.process.equipment.valve.ThrottlingValve
Separator = jneqsim.process.equipment.separator.Separator
ProcessSystem = jneqsim.process.processmodel.ProcessSystem
ProcessLinkedMPC = jneqsim.process.mpc.ProcessLinkedMPC
fluid = SystemSrkEos(298.15, 50.0)
fluid.addComponent("methane", 0.8)
fluid.addComponent("ethane", 0.1)
fluid.addComponent("propane", 0.05)
fluid.addComponent("n-pentane", 0.05)
fluid.setMixingRule("classic")
feed = Stream("feed", fluid)
feed.setFlowRate(100.0, "kg/hr")
feed.setTemperature(25.0, "C")
feed.setPressure(50.0, "bara")
valve = ThrottlingValve("inlet_valve", feed)
valve.setOutletPressure(30.0)
separator = Separator("separator", valve.getOutletStream())
process = ProcessSystem()
process.add(feed)
process.add(valve)
process.add(separator)
process.run()
mpc = ProcessLinkedMPC("separator-pressure", process)
mpc.addMV("inlet_valve", "opening", 0.0, 1.0, 0.1)
mpc.addCV("separator", "pressure", 30.0)
mpc.setConstraint("separator", "pressure", 20.0, 40.0)
mpc.identifyModel(60.0)
mpc.setPredictionHorizon(20)
mpc.setControlHorizon(5)
moves = mpc.calculate()
mpc.applyMoves()
Result extraction
| Output | Exact accessor | Units / meaning |
|---|---|---|
| Local gain model | getLinearizationResult(), then getGainMatrix(), getGain(cvName, mvName), getMvOperatingPoint(), getCvOperatingPoint() |
Gain units are output-unit per input-unit; keep named variable units consistent |
| Control demand | calculate() or getLastMoves() |
double[], one move per configured MV in declaration order; values follow the configured variable bounds/units |
| Process mutation | applyMoves() |
Applies the last calculated move set to the linked process equipment |
| State-space export | exportModel().toDiscreteStateSpace(sampleTime); model getSampleTime, getA/B/C/D |
Discrete sample time is seconds; matrix states/inputs/outputs inherit model variable definitions |
| VFM phase rates | VFMResult.getOilFlowRate(), getGasFlowRate(), getWaterFlowRate(), getTotalLiquidFlowRate() |
Sm3/d |
| VFM quality/uncertainty | getQuality(), getOilUncertainty(), getGasUncertainty(), getWaterUncertainty() |
HIGH, NORMAL, LOW, EXTRAPOLATED, INVALID; uncertainty record carries unit and bounds |
| Soft sensor | estimate() |
Default unit depends on PropertyType: e.g. density kg/m3, viscosity cP, pressure bara, GOR Sm3/Sm3 |
| Reconciliation | isConverged, getErrorMessage, getVariables, getConstraintResidualsBefore/After, getChiSquareStatistic, isGlobalTestPassed, getGrossErrors |
Residual arrays follow constraint insertion order; variable values preserve declared input units |
Gotchas
- Identify the MPC only after the process has a valid solved operating point.
calculate()beforeidentifyModel()throwsIllegalStateException;applyMoves()before a calculation also throws. ProcessLinearizerperturbs a local model; results can be misleading at hard bounds, discontinuities, phase transitions, or a non-converged base point. Re-check nonlinear behavior over the intended operating envelope.- MVs/CVs use the property access and unit behavior of the bound equipment variables. Use explicit physical bounds, rate limits, and compatible engineering units; don't assume a universal percent, bara, or temperature conversion.
ModelPredictiveControlleruses an internal first-order model and analytical constrained move calculation. It does not emulate a DCS, PLC, SIS, communications stack, alarm rationalization, or vendor controller execution environment.- State-space, Industrial MPC, and SubrModl exporters produce files/configuration for integration; they do not deploy, authenticate, or validate a target controller.
VirtualFlowMeterimplements a simplified differential-pressure multiplier (sqrt(abs(dP))) with a calibration factor, not a standards-based meter sizing/flow equation. Its output is an estimate; qualityHIGHis not a custody-transfer approval.- VFM returns
INVALIDwhen stream/fluid is absent or a flash fails. Phase-absent rates remain zero; distinguish a physical zero from an unavailable phase/model result. SoftSensor.estimate()returnsNaNwhen stream/fluid is unavailable, the flash fails, or a selected phase property cannot be evaluated. TestDouble.isFiniteand preserve the output unit.DataReconciliationEnginerequires more variables than constraints. Constraints are caller-defined linear rows with coefficients ordered exactly as variables were added; the engine does not derive a process flowsheet balance automatically.- Reconciliation failure returns a result with
isConverged()==falseand a message such asNo variables added,No constraints added, orNeed more variables ...; never report default values as reconciled measurements. SteadyStateDetector's R-statistic is a data-window screen. A steady-state verdict does not prove tag independence, sensor health, process stability outside the selected window, or calibration validity.
Validation / benchmarks
- Start from a converged steady state; test local gain signs and magnitudes against independent small positive/negative perturbations and the intended process direction.
- Check response bounds, move limits, control horizon, prediction horizon, sample time, quality constraints, and model-validity region before using moves in a study.
- Compare controller performance with
ControlsBenchmarkSuiteand reportControllerPerformanceMetrics; retain event history and failed scenarios. Benchmark completion is not DCS or functional-safety qualification. - Validate exported matrices by reconstructing the operating-point response and checking dimensions, named-variable ordering, and units. Test imports in the actual target platform before claiming interoperability.
- For VFM, compare against independent well tests across multiple operating points; report calibration range, uncertainty basis, and EXTRAPOLATED/INVALID cases.
- Run steady-state detection on selected, quality-screened signals; reconcile only after the feed/product balance equations, sigmas, degrees of freedom, and gross-error flags have been reviewed.
- For plant-data calibration and historian comparison, follow
neqsim-model-calibration-and-data-reconciliationandneqsim-plant-datarather than folding data acquisition into this controller layer.