Gas Turbine Performance Screening
Use this skill for public, educational gas-turbine performance screening. It corrects an ISO base rating for ambient temperature, site elevation, and inlet/exhaust pressure losses to estimate site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature so an agent can scope a driver-selection study before detailed package review.
When to Use
- When a user asks how much power a gas-turbine driver makes at site conditions versus its ISO rating.
- When an agent needs a quick site heat rate, fuel heat input, or exhaust mass flow estimate for waste-heat or HRSG scoping.
- When examples must run without confidential vendor performance maps or company package specs.
Inputs
iso_base_power_kw: ISO base-load shaft power rating in kW.
iso_heat_rate_kj_kwh: ISO base-load heat rate in kJ/kWh.
ambient_temperature_k: site ambient temperature in kelvin, default 288.15 (ISO reference).
site_elevation_m: site elevation above sea level in m, default 0.
relative_humidity: site relative humidity fraction, default 0.6 (small effect).
inlet_pressure_loss_mbar: inlet system pressure loss in mbar, default 10.
exhaust_pressure_loss_mbar: exhaust system pressure loss in mbar, default 10.
required_shaft_power_kw: optional driven-equipment shaft power in kW for the margin check.
Outputs
site_power_kw: derated site shaft power.
ambient_derate_factor: ambient-temperature power factor.
altitude_derate_factor: site-elevation power factor.
pressure_loss_derate_factor: combined inlet/exhaust pressure-loss power factor.
total_derate_factor: product of all derate factors.
site_heat_rate_kj_kwh: site heat rate after efficiency degradation.
thermal_efficiency: shaft thermal efficiency from the site heat rate.
fuel_heat_input_kw: fuel lower-heating-value heat input.
exhaust_mass_flow_kg_s: screening exhaust mass flow.
exhaust_temperature_k: screening exhaust temperature.
power_margin_ratio: site power divided by required shaft power, or null.
power_warning: ok, watch, insufficient-power, or no-rating.
assumptions: public assumptions used by the placeholder model.
Engineering Method
The Python class GasTurbinePerformanceModel uses open performance-derate relations only:
- ambient derate uses
f_amb = 1 - 0.007 (T_amb - 288.15), clamped at zero.
- altitude derate uses
f_alt = 1 - 1.1e-4 * elevation, from reduced barometric pressure.
- pressure-loss derate uses
f_inlet = 1 - 0.002 * dP_inlet and f_exhaust = 1 - 0.001 * dP_exhaust.
- site power uses
P_site = P_iso * f_amb * f_alt * f_inlet * f_exhaust * f_humidity.
- site heat rate uses
HR_site = HR_iso (1 + 0.5 (1 - f_total)) so efficiency falls with derate.
- fuel heat input uses
Q_fuel = P_site * HR_site / 3600.
- exhaust mass flow uses a fixed specific-flow factor
m_exh = P_site * 0.003.
This is educational and screening-only logic. It assumes linear derates, a fixed specific exhaust flow, and a typical exhaust temperature. It is not a replacement for validated gas-turbine performance models or qualified package review.
Python Usage Pattern
from gas_turbine_performance_screening import GasTurbinePerformanceModel
model = GasTurbinePerformanceModel()
result = model.evaluate(
iso_base_power_kw=30000.0,
iso_heat_rate_kj_kwh=9500.0,
ambient_temperature_k=303.15,
site_elevation_m=50.0,
required_shaft_power_kw=26000.0,
)
print(result.site_power_kw)
print(result.site_heat_rate_kj_kwh)
print(result.power_warning)
Related NeqSim Functionality
For validated power-generation calculations, redirect to NeqSim classes:
neqsim.process.equipment.powergeneration.GasTurbine — gas-turbine driver model with fuel and exhaust calculations.
neqsim.process.equipment.powergeneration.HRSG — heat-recovery steam generator using turbine exhaust.
neqsim.process.equipment.powergeneration.CombinedCycleSystem — combined-cycle integration of turbine and steam systems.
This skill is a public triage layer that decides when to invoke a validated gas-turbine model.
Validation Checklist
Common Mistakes
| Symptom |
Cause |
Fix |
| Site power above ISO rating |
Ambient below 288.15 K |
Screening caps uprate; treat sub-ISO gains conservatively |
| Power margin missing |
No required shaft power supplied |
Provide required_shaft_power_kw for the margin check |
| Exhaust flow looks flat |
Fixed specific-flow factor used |
Use a validated gas-turbine model for HRSG sizing |
Limitations
- No proprietary vendor performance maps, fuel composition effects, or company specs are included.
- Derates are linear screening factors; part-load, water injection, and DLE effects are not modelled.
- Exhaust mass flow and temperature use fixed screening assumptions, not a heat-and-mass balance.
Related Skills
neqsim-weather-data - live or historical site ambient temperature (and elevation from
location resolution) to feed ambient_temperature_k/site_elevation_m instead of an assumed value.
References
1---2name: neqsim-gas-turbine-performance-screening-23calculation_basis: "screening"4version: "0.1.0"5description: "Educational gas-turbine performance screening using open ISO 3977 / GL1029 style derate factors. USE WHEN: a task needs a public, screening-level estimate of site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature for a gas-turbine driver before detailed package selection."6last_verified: "2026-06-25"7requires:8 python_packages: []9 java_packages: []10 env: []11 network: []12metadata:13 source: https://skillmd.com/skills/equinor/neqsim-gas-turbine-performance-screening-214---1516# Gas Turbine Performance Screening1718Use this skill for public, educational gas-turbine performance screening. It corrects an ISO base rating for ambient temperature, site elevation, and inlet/exhaust pressure losses to estimate site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature so an agent can scope a driver-selection study before detailed package review.1920## When to Use2122- When a user asks how much power a gas-turbine driver makes at site conditions versus its ISO rating.23- When an agent needs a quick site heat rate, fuel heat input, or exhaust mass flow estimate for waste-heat or HRSG scoping.24- When examples must run without confidential vendor performance maps or company package specs.2526## Inputs2728- `iso_base_power_kw`: ISO base-load shaft power rating in kW.29- `iso_heat_rate_kj_kwh`: ISO base-load heat rate in kJ/kWh.30- `ambient_temperature_k`: site ambient temperature in kelvin, default 288.15 (ISO reference).31- `site_elevation_m`: site elevation above sea level in m, default 0.32- `relative_humidity`: site relative humidity fraction, default 0.6 (small effect).33- `inlet_pressure_loss_mbar`: inlet system pressure loss in mbar, default 10.34- `exhaust_pressure_loss_mbar`: exhaust system pressure loss in mbar, default 10.35- `required_shaft_power_kw`: optional driven-equipment shaft power in kW for the margin check.3637## Outputs3839- `site_power_kw`: derated site shaft power.40- `ambient_derate_factor`: ambient-temperature power factor.41- `altitude_derate_factor`: site-elevation power factor.42- `pressure_loss_derate_factor`: combined inlet/exhaust pressure-loss power factor.43- `total_derate_factor`: product of all derate factors.44- `site_heat_rate_kj_kwh`: site heat rate after efficiency degradation.45- `thermal_efficiency`: shaft thermal efficiency from the site heat rate.46- `fuel_heat_input_kw`: fuel lower-heating-value heat input.47- `exhaust_mass_flow_kg_s`: screening exhaust mass flow.48- `exhaust_temperature_k`: screening exhaust temperature.49- `power_margin_ratio`: site power divided by required shaft power, or `null`.50- `power_warning`: `ok`, `watch`, `insufficient-power`, or `no-rating`.51- `assumptions`: public assumptions used by the placeholder model.5253## Engineering Method5455The Python class `GasTurbinePerformanceModel` uses open performance-derate relations only:5657- ambient derate uses `f_amb = 1 - 0.007 (T_amb - 288.15)`, clamped at zero.58- altitude derate uses `f_alt = 1 - 1.1e-4 * elevation`, from reduced barometric pressure.59- pressure-loss derate uses `f_inlet = 1 - 0.002 * dP_inlet` and `f_exhaust = 1 - 0.001 * dP_exhaust`.60- site power uses `P_site = P_iso * f_amb * f_alt * f_inlet * f_exhaust * f_humidity`.61- site heat rate uses `HR_site = HR_iso (1 + 0.5 (1 - f_total))` so efficiency falls with derate.62- fuel heat input uses `Q_fuel = P_site * HR_site / 3600`.63- exhaust mass flow uses a fixed specific-flow factor `m_exh = P_site * 0.003`.6465This is educational and screening-only logic. It assumes linear derates, a fixed specific exhaust flow, and a typical exhaust temperature. It is not a replacement for validated gas-turbine performance models or qualified package review.6667## Python Usage Pattern6869```python70from gas_turbine_performance_screening import GasTurbinePerformanceModel7172model = GasTurbinePerformanceModel()73result = model.evaluate(74 iso_base_power_kw=30000.0,75 iso_heat_rate_kj_kwh=9500.0,76 ambient_temperature_k=303.15,77 site_elevation_m=50.0,78 required_shaft_power_kw=26000.0,79)8081print(result.site_power_kw)82print(result.site_heat_rate_kj_kwh)83print(result.power_warning)84```8586## Related NeqSim Functionality8788For validated power-generation calculations, redirect to NeqSim classes:8990- `neqsim.process.equipment.powergeneration.GasTurbine` — gas-turbine driver model with fuel and exhaust calculations.91- `neqsim.process.equipment.powergeneration.HRSG` — heat-recovery steam generator using turbine exhaust.92- `neqsim.process.equipment.powergeneration.CombinedCycleSystem` — combined-cycle integration of turbine and steam systems.9394This skill is a public triage layer that decides when to invoke a validated gas-turbine model.9596## Validation Checklist9798- [ ] ISO base power and heat rate are positive.99- [ ] Ambient temperature is positive and elevation is non-negative.100- [ ] Tests cover ambient derate, the power margin, the fuel/efficiency estimate, and invalid input.101- [ ] Results are described as educational screening indicators.102- [ ] Real driver selection is redirected to validated NeqSim power-generation classes and qualified review.103104## Common Mistakes105106| Symptom | Cause | Fix |107| --- | --- | --- |108| Site power above ISO rating | Ambient below 288.15 K | Screening caps uprate; treat sub-ISO gains conservatively |109| Power margin missing | No required shaft power supplied | Provide `required_shaft_power_kw` for the margin check |110| Exhaust flow looks flat | Fixed specific-flow factor used | Use a validated gas-turbine model for HRSG sizing |111112## Limitations113114- No proprietary vendor performance maps, fuel composition effects, or company specs are included.115- Derates are linear screening factors; part-load, water injection, and DLE effects are not modelled.116- Exhaust mass flow and temperature use fixed screening assumptions, not a heat-and-mass balance.117118## Related Skills119120- `neqsim-weather-data` - live or historical site ambient temperature (and elevation from121 location resolution) to feed `ambient_temperature_k`/`site_elevation_m` instead of an assumed value.122123## References124125- ISO 3977, Gas turbines — Procurement.126- ISO 2314, Gas turbines — Acceptance tests.127- NeqSim repository: https://github.com/equinor/neqsim