Produced Water and Solids Separation
When to use this
- Screen a produced-water treatment train, oil-in-water outlet, or discharge volume.
- Size/check hydrocyclone liners, differential pressure, turndown, or droplet response.
- Represent gas flotation, solids splitting, centrifuge dewatering, filter pressure drop, or sulfur removal.
- Evaluate crystallization, liquid-liquid extraction, cryogenic separation, or end-flash where those unit models fit the stated process.
- Evaluate gas/liquid mass transfer over a pipeline with the evaporation/dissolution studies.
- Estimate dissolved-gas release from produced water with the degassing utility.
This skill owns separation and treatment equipment. It does not own chemical selection or dose optimization. Route demulsifier dose-response, lag, compatibility, and recommended dose to neqsim-production-chemistry; reuse its result rather than repeating that model here. Build ion composition and scale chemistry with neqsim-electrolyte-systems.
Class map
| Class family | Package | What it does | Verified entry points / result methods |
|---|---|---|---|
Produced-water stage screen: ProducedWaterTreatmentTrain, WaterTreatmentStage |
neqsim.process.equipment.watertreatment |
Applies stated fractional stage efficiencies and reports a screening OiW concentration, recovery, and discharge status. | setInletOilConcentration, setWaterFlowRate, addStage, run, getOilInWaterMgL, getOverallEfficiency, isDischargeCompliant |
Hydrocyclone: water-treatment Hydrocyclone |
neqsim.process.equipment.watertreatment |
Estimates liner capacity, d50/droplet response, DP adequacy, design utilization, and oil-in-water performance. | calcNumberOfLiners, calcD50FromConditions, estimateEfficiencyFromConditions, getEfficiencyForDropletSize, getOutletOilMgL, getRejectFlowM3h, getDesignValidationSummary |
Gas flotation: GasFlotationUnit |
neqsim.process.equipment.watertreatment |
Separator-derived flotation stage with configurable stages and performance inputs. | new GasFlotationUnit(name, inletStream), setNumberOfStages, getOilRemovalEfficiency |
OiW measurement/compliance: OilInWaterAnalyzerDriftModel, OilInWaterMonthlyComplianceMonitor |
neqsim.process.equipment.watertreatment |
Simulates analyzer bias/drift/noise and water-volume-weighted monthly sample status. | measure, correctMeasuredValue, measureConservative, isCalibrationDue, addSample, calculateStatus, getWeightedAverageMgL |
Solid phase splitting: SolidsSeparator, SolidsCentrifuge |
neqsim.process.equipment.separator |
Separates modeled solid components and reports solids/liquid outlets; centrifuge exposes g-force-based inputs. | setSolidsSplitFraction, setDefaultSolidsSplit, getSolidsOutStream, getLiquidOutStream, SolidsCentrifuge.setGForce |
Mechanical dewatering: RotaryVacuumFilter, PressureFilter, ScrewPress |
neqsim.process.equipment.separator |
Represents pressure/vacuum filtration and screw pressing with equipment-specific operating inputs. | setVacuumPressure, setFilterArea, setOperatingPressure, setScrewSpeed, setCompressionRatio |
Filter service and curves: Filter, CharCoalFilter, SulfurFilter, FilterPerformanceCurve, FilterPressureDropCurve |
neqsim.process.equipment.filter |
Applies pressure-drop and particle-removal curves; sulfur filter reports sulfur removal and change interval. | setDeltaP, setPressureDropModel, setPoints, getRemovalEfficiency, getPressureDrop, getSolidSulfurRemovalRate |
Crystallization/extraction: Crystallizer, LiquidLiquidExtractor |
neqsim.process.equipment.separator |
Produces crystal/mother-liquor streams or extract/raffinate streams from configured unit inputs. | setSolidRecovery, setTargetSolute, getCrystalStream, getMotherLiquorStream, setNumberOfStages, getExtractStream, getRaffinateStream |
Adjacent separator duties: TwoPhaseSeparator, CryogenicSeparator, EndFlash, SeparatorCapacityAssessment |
neqsim.process.equipment.separator |
Handles gas/liquid separation, cryogenic impurity limits/end flash, and explicit capacity assessment. | setMaxCO2MolFrac, setMaxWaterPpm, getN2InLNGMolFrac, SeparatorCapacityAssessment.getStatus, getDiagnostic |
Pipeline phase transfer: PipelineEvaporationStudy, PipelineDissolutionStudy |
neqsim.process.equipment.pipeline.evaporation |
Integrates component transfer and heat balance along a configured pipe length. | Constructors take (SystemInterface, PipelineEvaporationConfig); inspect PipelineEvaporationResult.getProfile and balance/convergence fields |
Produced-water gas release: ProducedWaterDegassingSystem |
neqsim.process.equipment.util |
Screens dissolved-gas release from water using explicit flow, temperature, inlet, and degasser pressure inputs. | setWaterFlowRate(value, unit), setWaterTemperature(value, unit), setInletPressure(value, unit), setDegasserPressure(value, unit) |
Build pattern
ProducedWaterTreatmentTrain is a deterministic screening stage model. The stage efficiencies are user inputs as fractions from 0 to 1; they are not derived from hydrocyclone geometry. The example's flow and inlet OiW data are explicit.
ProducedWaterTreatmentTrain train = new ProducedWaterTreatmentTrain("PW train");
train.setWaterFlowRate(416.67); // m3/h
train.setInletOilConcentration(1000.0); // mg/L
train.addStage(new WaterTreatmentStage("primary", StageType.HYDROCYCLONE, 0.95));
train.addStage(new WaterTreatmentStage("secondary", StageType.FLOTATION, 0.80));
train.run();
double outletOiwMgL = train.getOilInWaterMgL();
boolean withinBuiltInLimit = train.isDischargeCompliant();
Equivalent Python class lookup:
from neqsim import jneqsim
ProducedWaterTreatmentTrain = jneqsim.process.equipment.watertreatment.ProducedWaterTreatmentTrain
StageType = ProducedWaterTreatmentTrain.StageType
WaterTreatmentStage = ProducedWaterTreatmentTrain.WaterTreatmentStage
train = ProducedWaterTreatmentTrain("PW train")
train.setWaterFlowRate(416.67) # m3/h
train.setInletOilConcentration(1000.0) # mg/L
train.addStage(WaterTreatmentStage("primary", StageType.HYDROCYCLONE, 0.95))
train.addStage(WaterTreatmentStage("secondary", StageType.FLOTATION, 0.80))
train.run()
outlet_oiw_mg_l = train.getOilInWaterMgL()
within_built_in_limit = train.isDischargeCompliant()
Analyzer and monthly-monitor pattern
Use the analyzer model to expose measurement bias and drift, then pass a corrected or conservative measured value and its sampled water volume to the monthly monitor. This is a monitoring calculation, not a chemical-dose recommendation.
OilInWaterAnalyzerDriftModel analyzer = new OilInWaterAnalyzerDriftModel();
double measuredMgL = analyzer.measure(25.0, 10.0);
double correctedMgL = analyzer.correctMeasuredValue(measuredMgL, 10.0);
OilInWaterMonthlyComplianceMonitor monitor = new OilInWaterMonthlyComplianceMonitor();
monitor.setMonthlyLimitMgL(30.0);
monitor.setProjectedDailyWaterVolumeM3(1000.0);
monitor.addSample(correctedMgL, 1000.0);
OilInWaterMonthlyComplianceMonitor.MonthlyStatus status = monitor.calculateStatus(10);
double weightedMeanMgL = monitor.getWeightedAverageMgL();
Select the separation model
- Use the treatment train when the available basis is inlet OiW, water flow, and stated stage efficiencies.
- Use the hydrocyclone equipment when feed stream phases, DP, liner count, d50, and outlet response are part of the question.
- Use
SolidsSeparatorfor component-level solid splits; do not infer a particle-size cut from a split fraction. - Use filter curves when particle-size capture or flow-dependent pressure drop is known from the selected element/test data.
- Use the pipeline evaporation/dissolution studies only when the inlet has the required gas/liquid phase basis and transfer geometry.
For a mechanistic hydrocyclone case, use the water-treatment class with an inlet stream: new Hydrocyclone(name, inletStream), set/verify pressure drop and feed conditions, run it, and inspect both getDesignValidationSummary() and the calculated outlet. Do not confuse it with neqsim.process.equipment.separator.Hydrocyclone, which is a distinct separator-package class.
Result extraction
ProducedWaterTreatmentTrain.getOilInWaterMgL()andgetOilInWaterPpm()return mg/L and ppm respectively; the class documents them as numerically equivalent for water.getOverallEfficiency()is a fraction from 0 to 1;getRecoveredOilM3h()is m3/h;getAnnualOilDischargeTonnes(hours)returns tonnes for the supplied annual operating hours.isDischargeCompliant()checks the class's built-inNCS_OIW_LIMIT_MGLof 30 mg/L. UseisCompliantWith(limitMgL)for a different declared limit; do not present the built-in default as a project-specific permit.- Water-treatment
Hydrocyclone.getD50Microns()andgetEfficiencyForDropletSize(microns)use microns;getPressureDropBar()is bar; capacity and reject-flow getters are m3/h;getOutletOilMgL()is mg/L. OilInWaterMonthlyComplianceMonitor.getWeightedAverageMgL()is a water-volume-weighted mg/L result. Preserve sample volume and status, not only the mean.Filter.getDeltaP()returns the internal pressure-drop value in bar.setDeltaP(value, unit)converts a differential-pressure unit to bar; filter curve methods take particle size in micrometres and flow in m3/hr as named by their parameters.PipelineEvaporationResult.getProfile()contains distance-indexed profile points; check completion, component balance, energy balance, and warnings before reporting transfer distance.
Gotchas
ProducedWaterDegassingSystem.setTunedInteractionParameters(true)throws before changing state. Use defaults (false); legacy serialized true flags also fail atbuild()and bothrun()entry points. The old constants were never applied and do not define a validated model.setSalinitystores metadata only. Do not claim field accuracy, salt effects, or reporting qualification for this screening builder. See the supported-model guide andProducedWaterDegassingTuningTest/ProducedWaterDegassingDocumentationTest.The stage train computes sequential remaining concentration as
Cout = Cin * (1 - efficiency)and expects each efficiency in 0-1, not percent. It uses a default oil density of 850 kg/m3 for recovered-oil estimates.The train's
getOverallEfficiency()divides by inlet OiW. A zero inlet concentration can yieldNaN; set a positive, measured inlet basis and guard zero before reporting efficiency.When an inlet stream is supplied, the train reads aqueous volume and oil mass for its calculation but creates outlet streams by cloning the inlet fluid. Those streams are not a component-by-component physical separation result; do not use them to claim a closed process mass balance.
The default discharge threshold is a code default, not a complete permit. Monthly weighted monitoring and conservative analyzer readings are evidence models, not laboratory certification.
The
watertreatment.Hydrocycloneandseparator.Hydrocyclonenames refer to different classes. State the package whenever you select one.SolidsSeparatorsplit fractions must be within 0 and 1. Filter performance-curve points require matching non-empty arrays, increasing particle sizes, and beta ratios >= 1; pressure-drop curve flow points must increase and pressure drops must be non-decreasing.PipelineEvaporationStudyrequires an explicit gas and liquid phase, gas in phase 0, and a supported dispersed phase. It rejects missing/invalid phases and reports energy-balance convergence failures; do not hide those warnings.No
validateSetup()override was found in the water-treatment/filter/evaporation classes covered here. Use the Hydrocyclone design summary, validated setters, and explicit stream/phase/balance checks instead.Demulsifier dose response, dose lag, and dose recommendation belong to
neqsim-production-chemistry; this skill does not prescribe chemical dosage.
Validation / benchmarks
ProducedWaterTreatmentTrainTestchecks sequential OiW reduction, compliance, conversion, annual discharge, and reporting.WaterTreatmentEquipmentTestchecks hydrocyclone d50, DP, capacity, and droplet-size response.OilInWaterDecisionSupportTestcovers analyzer drift and volume-weighted monthly monitoring; its dose-response and dose-optimizer cases are owned byneqsim-production-chemistry.- For any case, compare inlet/outlet concentration with measured data, check water throughput and operating time, inspect separator/filter capacity and pressure drop, and distinguish model status from permit acceptance.
- These models do not replace vendor guarantees, particle-size distribution testing, detailed solids rheology, discharge permitting, or site-specific equipment design. Several are screening or empirical models with declared inputs.
Related skills
neqsim-production-chemistry— demulsifier and other chemical dose/compatibility workflows; do not duplicate dose calculations here.neqsim-electrolyte-systems— electrolyte fluid setup, brine chemistry, and scale prediction.neqsim-process-modeling— process stream/equipment wiring and mass-balance checks.neqsim-flow-assurance— pipeline threats, scale deposition, and transport context.neqsim-separator-modelling— general separator gas/liquid capacity screening.