Match corresponding untargeted metabolomic features across two LC-MS datasets using retention time and mass-to-charge ratio alignment. This skill bridges two independent feature tables to enable comparative metabolomics analysis by identifying and linking chemically identical or highly similar features.
When to use
You have two separate LC-MS untargeted metabolomic feature tables (e.g., from different sample cohorts, instrument runs, or data processing pipelines) and need to establish one-to-one correspondences between features to perform downstream comparative analysis, statistical testing, or combined feature annotation.
When NOT to use
- Input is already a single unified feature table or features are already matched across datasets
- Only one LC-MS dataset is available or comparative feature alignment is not the analysis goal
- Features lack reliable retention time or mass-to-charge ratio measurements (e.g., very low resolution or high noise)
Inputs
- LC-MS untargeted metabolomic feature table 1 (retention time, m/z, intensity matrix)
- LC-MS untargeted metabolomic feature table 2 (retention time, m/z, intensity matrix)
Outputs
- Matched feature table with feature correspondence links and matching scores
- Feature pairing indices or identifiers from both input datasets
How to apply
Load both LC-MS untargeted metabolomic feature datasets (containing retention time and m/z values) into Matlab. Initialize the M2S package with both feature tables as input parameters. Execute the M2S matching algorithm, which identifies feature correspondences by computing similarity scores based on retention time proximity and mass-to-charge ratio alignment. The algorithm links features across datasets where their physicochemical signatures (RT and m/z) are sufficiently similar. Export the resulting matched feature table, which contains feature IDs or indices from both datasets, their correspondence links, and matching confidence scores. Validate the output by inspecting the matching score distribution and spot-checking representative matches against the original RT and m/z values.
Related tools
Evaluation signals
- Matching score distribution is unimodal and concentrated in the expected range (indicate by visual inspection of score histogram)
- Number of matched feature pairs is reasonable relative to the sizes of input feature tables (e.g., not zero or 100% of the smaller table)
- Spot-check: randomly selected matched pairs exhibit minimal retention time drift (within instrument calibration tolerance) and m/z error (within mass accuracy of the instrument)
- Matched features can be validated against independent chemical standards or orthogonal identification methods (e.g., MS/MS spectra, reference databases)
- Output table contains all required columns: feature IDs/indices from both datasets, matching scores, and linked RT and m/z values
Limitations
- Matching accuracy depends on the quality and reproducibility of retention time measurements and m/z calibration across the two LC-MS runs; poorly calibrated instruments or drifting RT will reduce matching sensitivity
- The algorithm may fail or produce false matches when features have similar m/z but different chemical identity (isomers, isobars) or when RT variation exceeds expected instrument tolerance
- No guidance provided in the README or article on parameter tuning (e.g., RT tolerance window, m/z error threshold) for different instrumental platforms or metabolite classes
Evidence
- [other] M2S is a Matlab package designed to match untargeted metabolomic features of two LC-MS datasets: "Matlab package to match untargeted metabolomic features of two LC-MS datasets"
- [other] The M2S algorithm identifies and links corresponding features across the two datasets based on retention time and mass-to-charge ratio similarity: "Execute the M2S matching algorithm to identify and link corresponding features across the two datasets based on retention time and mass-to-charge ratio similarity"
- [other] The workflow produces a matched feature table containing feature correspondences and matching scores as the primary output: "Generate and export the matched feature table containing feature correspondences and matching scores"
1---2name: untargeted-metabolomics-data-processing-23description: Use when you have two separate LC-MS untargeted metabolomic feature tables (e.4license: CC-BY-4.05---67# untargeted-metabolomics-data-processing89## Summary1011Match corresponding untargeted metabolomic features across two LC-MS datasets using retention time and mass-to-charge ratio alignment. This skill bridges two independent feature tables to enable comparative metabolomics analysis by identifying and linking chemically identical or highly similar features.1213## When to use1415You have two separate LC-MS untargeted metabolomic feature tables (e.g., from different sample cohorts, instrument runs, or data processing pipelines) and need to establish one-to-one correspondences between features to perform downstream comparative analysis, statistical testing, or combined feature annotation.1617## When NOT to use1819- Input is already a single unified feature table or features are already matched across datasets20- Only one LC-MS dataset is available or comparative feature alignment is not the analysis goal21- Features lack reliable retention time or mass-to-charge ratio measurements (e.g., very low resolution or high noise)2223## Inputs2425- LC-MS untargeted metabolomic feature table 1 (retention time, m/z, intensity matrix)26- LC-MS untargeted metabolomic feature table 2 (retention time, m/z, intensity matrix)2728## Outputs2930- Matched feature table with feature correspondence links and matching scores31- Feature pairing indices or identifiers from both input datasets3233## How to apply3435Load both LC-MS untargeted metabolomic feature datasets (containing retention time and m/z values) into Matlab. Initialize the M2S package with both feature tables as input parameters. Execute the M2S matching algorithm, which identifies feature correspondences by computing similarity scores based on retention time proximity and mass-to-charge ratio alignment. The algorithm links features across datasets where their physicochemical signatures (RT and m/z) are sufficiently similar. Export the resulting matched feature table, which contains feature IDs or indices from both datasets, their correspondence links, and matching confidence scores. Validate the output by inspecting the matching score distribution and spot-checking representative matches against the original RT and m/z values.3637## Related tools3839- **M2S** (Matlab package executing the feature matching algorithm using retention time and m/z similarity) — https://github.com/rjdossan/M2S4041## Evaluation signals4243- Matching score distribution is unimodal and concentrated in the expected range (indicate by visual inspection of score histogram)44- Number of matched feature pairs is reasonable relative to the sizes of input feature tables (e.g., not zero or 100% of the smaller table)45- Spot-check: randomly selected matched pairs exhibit minimal retention time drift (within instrument calibration tolerance) and m/z error (within mass accuracy of the instrument)46- Matched features can be validated against independent chemical standards or orthogonal identification methods (e.g., MS/MS spectra, reference databases)47- Output table contains all required columns: feature IDs/indices from both datasets, matching scores, and linked RT and m/z values4849## Limitations5051- Matching accuracy depends on the quality and reproducibility of retention time measurements and m/z calibration across the two LC-MS runs; poorly calibrated instruments or drifting RT will reduce matching sensitivity52- The algorithm may fail or produce false matches when features have similar m/z but different chemical identity (isomers, isobars) or when RT variation exceeds expected instrument tolerance53- No guidance provided in the README or article on parameter tuning (e.g., RT tolerance window, m/z error threshold) for different instrumental platforms or metabolite classes5455## Evidence5657- [other] M2S is a Matlab package designed to match untargeted metabolomic features of two LC-MS datasets: "Matlab package to match untargeted metabolomic features of two LC-MS datasets"58- [other] The M2S algorithm identifies and links corresponding features across the two datasets based on retention time and mass-to-charge ratio similarity: "Execute the M2S matching algorithm to identify and link corresponding features across the two datasets based on retention time and mass-to-charge ratio similarity"59- [other] The workflow produces a matched feature table containing feature correspondences and matching scores as the primary output: "Generate and export the matched feature table containing feature correspondences and matching scores"