Performing Power Grid Cybersecurity Assessment
Overview
Cybersecurity skill for performing power grid cybersecurity assessment. Follows industry best practices and security standards.
When to Use
Trigger phrases:
"performing power grid cybersecurity assessment"
"This skill covers conducting cybersecurity assessments of electric power grid in"
When conducting periodic cybersecurity assessments of power grid facilities per NERC CIP requirements
When assessing substation automation systems using IEC 61850 GOOSE and MMS protocols
When evaluating the security of an Energy Management System (EMS) or SCADA control center
When assessing synchrophasor (PMU) networks and wide-area monitoring systems
When preparing for regional entity compliance audits or internal security reviews
Do not use for non-BES systems below NERC registration thresholds, for general OT assessment without power grid specifics (see performing-ot-network-security-assessment), or for physical security assessment of generation facilities without cyber scope.
When NOT to Use
- When you lack proper authorization for testing
- For production systems without change management
- When the task requires legal or compliance expertise beyond technical scope
Prerequisites
- Understanding of electric power grid architecture (generation, transmission, distribution)
- Familiarity with NERC CIP standards and BES Cyber System categorization
- Knowledge of power grid protocols (IEC 61850, IEC 60870-5-104, DNP3, ICCP/TASE.2)
- Passive monitoring tools for substation network traffic analysis
- Access to EMS/SCADA architecture documentation and network diagrams
Workflow
# Example: IOC detection
import re
IOC_PATTERNS = {
"ip": r"\b(?:\d{1,3}\.){3}\d{1,3}\b",
"domain": r"\b[a-z0-9-]+\.[a-z]{2,}\b",
"hash_md5": r"\b[a-f0-9]{32}\b",
"hash_sha256": r"\b[a-f0-9]{64}\b",
}
def extract_iocs(text: str) -> dict:
return {k: re.findall(v, text) for k, v in IOC_PATTERNS.items()}
- Plan Operations — Define objectives, scope, and success criteria for power grid cybersecurity assessment operations.
- Prepare Environment — Set up tools, access, and data sources required for power grid cybersecurity assessment.
- Execute Core Workflow — Perform the power grid cybersecurity assessment operations following established procedures.
- Validate Results — Verify that results meet quality standards and objectives.
- Report Findings — Document results, observations, and recommendations.
- Follow Up — Track remediation actions and verify fixes where applicable.
Tools
- Analysis Platform — Data processing and visualization
- Collaboration Tools — Team coordination and knowledge sharing
Process
- Reconnaissance — Gather target information, identify attack surface, enumerate services
- Analysis/Exploitation — Execute the technique, analyze results, document findings
- Reporting — Document IOCs, write findings, provide remediation recommendations
Verification
Anti-Rationalization Table
| Rationalization |
Reality |
| "We are too small to be targeted" |
Automated attacks target everyone. Size does not matter. |
| "Security slows us down" |
A breach slows you down 100x more. Build security in from the start. |
| "We will fix it after launch" |
Vulnerabilities in production are exploited within hours. Fix before deploy. |
1---2name: performing-power-grid-cybersecurity-assessment3description: Use when this skill covers conducting cybersecurity assessments of electric power grid infrastructure including generation facilities, transmission substations, distribution systems, and energy management system (EMS) control centers. It addresses NERC CIP compliance verification, substation automation security, IEC 61850 protocol analysis, synchrophasor (PMU) network security, and the unique threat landscape targeting power grid operations as demonstrated by Industroyer/CrashOverride and rel...4license: Apache-2.05---67# Performing Power Grid Cybersecurity Assessment89## Overview1011Cybersecurity skill for performing power grid cybersecurity assessment. Follows industry best practices and security standards.1213## When to Use14**Trigger phrases:**15- "performing power grid cybersecurity assessment"16- "This skill covers conducting cybersecurity assessments of electric power grid in"171819- When conducting periodic cybersecurity assessments of power grid facilities per NERC CIP requirements20- When assessing substation automation systems using IEC 61850 GOOSE and MMS protocols21- When evaluating the security of an Energy Management System (EMS) or SCADA control center22- When assessing synchrophasor (PMU) networks and wide-area monitoring systems23- When preparing for regional entity compliance audits or internal security reviews2425**Do not use** for non-BES systems below NERC registration thresholds, for general OT assessment without power grid specifics (see performing-ot-network-security-assessment), or for physical security assessment of generation facilities without cyber scope.262728## When NOT to Use2930- When you lack proper authorization for testing31- For production systems without change management32- When the task requires legal or compliance expertise beyond technical scope333435## Prerequisites3637- Understanding of electric power grid architecture (generation, transmission, distribution)38- Familiarity with NERC CIP standards and BES Cyber System categorization39- Knowledge of power grid protocols (IEC 61850, IEC 60870-5-104, DNP3, ICCP/TASE.2)40- Passive monitoring tools for substation network traffic analysis41- Access to EMS/SCADA architecture documentation and network diagrams4243## Workflow4445```python46# Example: IOC detection47import re4849IOC_PATTERNS = {50 "ip": r"\b(?:\d{1,3}\.){3}\d{1,3}\b",51 "domain": r"\b[a-z0-9-]+\.[a-z]{2,}\b",52 "hash_md5": r"\b[a-f0-9]{32}\b",53 "hash_sha256": r"\b[a-f0-9]{64}\b",54}5556def extract_iocs(text: str) -> dict:57 return {k: re.findall(v, text) for k, v in IOC_PATTERNS.items()}58```59601. **Plan Operations** — Define objectives, scope, and success criteria for power grid cybersecurity assessment operations.612. **Prepare Environment** — Set up tools, access, and data sources required for power grid cybersecurity assessment.623. **Execute Core Workflow** — Perform the power grid cybersecurity assessment operations following established procedures.634. **Validate Results** — Verify that results meet quality standards and objectives.645. **Report Findings** — Document results, observations, and recommendations.656. **Follow Up** — Track remediation actions and verify fixes where applicable.6667## Tools6869- **Analysis Platform** — Data processing and visualization70- **Collaboration Tools** — Team coordination and knowledge sharing717273## Process74751. **Reconnaissance** — Gather target information, identify attack surface, enumerate services761. **Analysis/Exploitation** — Execute the technique, analyze results, document findings771. **Reporting** — Document IOCs, write findings, provide remediation recommendations7879## Verification8081- [ ] All power grid cybersecurity assessment procedures executed completely and documented82- [ ] Findings validated against multiple data sources83- [ ] False positives identified and filtered84- [ ] Results documented with evidence and timestamps85- [ ] Recommendations provided with risk-based prioritization8687## Anti-Rationalization Table8889| Rationalization | Reality |90|---|---|91| "We are too small to be targeted" | Automated attacks target everyone. Size does not matter. |92| "Security slows us down" | A breach slows you down 100x more. Build security in from the start. |93| "We will fix it after launch" | Vulnerabilities in production are exploited within hours. Fix before deploy. |