Linkr reboot and BIOS entry
Use this skill when the user needs to reach BIOS setup, a one-time boot menu, or another firmware-adjacent destination on a machine attached to Linkr.
This is a high-risk workflow. Read tool contract, safety rules, and qualification notes first.
Required facts before execution
Establish these facts explicitly:
- which configured profile is being used;
- the attached machine identity in
targetIdentity; - the desired destination: BIOS setup, one-time boot menu, recovery, or normal reboot;
- the evidence for the entry key, such as a visible on-screen prompt, vendor documentation, or operator confirmation;
- the reboot method that is actually available;
- whether updates, flashing, encryption setup, or filesystem repair are in progress.
If any destructive or high-risk background activity may be happening, stop. No update power cuts.
Plan first
- Use
statusandsnapshotto identify the current state. - Call
reboot.planto preview the intended reboot path. - Call
firmware.entry.planwith the exactjobobject you would later execute. - Restate the destination, chosen key, timing, and reboot anchor before execution.
Important: v0.1 does not promise automatic OS reboot integration. If there is no separately verified reboot path, the default anchor is operator-assisted.
Execution model
When authorised, execute only a bounded local job:
- start with
job.start; - provide
device_id; - provide
job.kind: "firmware-entry"; - send the selected key only;
- use a finite
duration_ms,capture_interval_ms,tap_start_ms,tap_interval_ms, andtap_duration_ms; - require
execute:true.
Example:
{
"action": "job.start",
"device_id": "lab-workstation-a",
"job": {
"kind": "firmware-entry",
"duration_ms": 15000,
"capture_interval_ms": 1000,
"key": "F2",
"key_evidence": "Splash prompt says F2 for Setup.",
"tap_start_ms": 500,
"tap_interval_ms": 250,
"tap_duration_ms": 4000
},
"execute": true
}
The job exists to avoid one-LLM-turn-per-tap timing errors. It is not permission to keep pressing forever.
Detection model
Firmware detection is an agent judgement from snapshots, not a numeric heuristic that declares success automatically.
After the tap burst:
- stop further key taps;
- inspect subsequent snapshots for visible firmware or boot-menu evidence;
- if normal OS boot continues, report a missed window and tune one timing parameter at a time;
- if the screen is dark, separate no-signal, stale capture, display-mode switch, and machine-off hypotheses.
There is no built-in learned timing system yet.
Reboot distinctions
Do not blur these cases together:
- ordinary OS reboot;
- forced reset or power cycle;
- Linkr appliance reboot;
- HID reinitialisation.
Ctrl+Alt+Delete is not a universal safe reboot fallback.
Do not use unless verified
Until a real adapter is documented and qualified, treat these as unavailable for this workflow:
power.presspower.resetpower.cycledevice.reboot
Return unsupported rather than guessing.
Cancellation and recovery
job.cancel may return cancellation_requested:true before the job has fully settled. If an in-flight input may have been interrupted, observe first and use input.release only when justified.
Evidence to keep
Record in your narrative:
- chosen profile and
targetIdentity; - destination and entry-key evidence;
- the exact planned timing window;
- whether execution used an operator-assisted reboot anchor;