1---2name: "quality-manager-qms-iso13485"3description: ISO 13485 Quality Management System implementation and maintenance for medical device organizations. Provides QMS design, documentation control, internal auditing, CAPA management, and certification support. Use when working with medical device quality systems, preparing for ISO 13485 audits, managing regulatory compliance documentation, setting up corrective actions, or building audit preparation programs. Useful for quality management, audit preparation, regulatory compliance, medical device documentation, and corrective action workflows.4metadata:5 source: https://skillmd.com/skills/slipcast-dev/quality-manager-qms-iso134856 triggers:7 - ISO 134858 - QMS implementation9 - quality management system10 - document control11 - internal audit12 - management review13 - quality manual14 - CAPA process15 - process validation16 - design control17 - supplier qualification18 - quality records19disable-model-invocation: true # skill-optimizer20---2122# Quality Manager - QMS ISO 13485 Specialist2324ISO 13485:2016 Quality Management System implementation, maintenance, and certification support for medical device organizations.2526---2728## Table of Contents2930- [QMS Implementation Workflow](#qms-implementation-workflow)31- [Document Control Workflow](#document-control-workflow)32- [Internal Audit Workflow](#internal-audit-workflow)33- [Process Validation Workflow](#process-validation-workflow)34- [Supplier Qualification Workflow](#supplier-qualification-workflow)35- [QMS Process Reference](#qms-process-reference)36- [Decision Frameworks](#decision-frameworks)37- [Tools and References](#tools-and-references)3839---4041## QMS Implementation Workflow4243Implement ISO 13485:2016 compliant quality management system from gap analysis through certification.4445### Workflow: Initial QMS Implementation46471. Conduct gap analysis against ISO 13485:2016 requirements482. Document current state vs. required state for each clause493. Prioritize gaps by:50 - Regulatory criticality51 - Risk to product safety52 - Resource requirements534. Develop implementation roadmap with milestones545. Establish Quality Manual per Clause 4.2.2:55 - QMS scope with justified exclusions56 - Process interactions57 - Procedure references586. Create required documented procedures — see [Mandatory Documented Procedures](#quick-reference-mandatory-documented-procedures) for the full list597. Deploy processes with training608. **Validation:** Gap analysis complete; Quality Manual approved; all required procedures documented and trained6162> Use the Gap Analysis Matrix template in [qms-process-templates.md](references/qms-process-templates.md) to document clause-by-clause current state, gaps, priority, and actions.6364### QMS Structure6566| Level | Document Type | Example |67|-------|---------------|---------|68| 1 | Quality Manual | QM-001 |69| 2 | Procedures | SOP-02-001 |70| 3 | Work Instructions | WI-06-012 |71| 4 | Records | Training records |7273---7475## Document Control Workflow7677Establish and maintain document control per ISO 13485 Clause 4.2.3.7879### Workflow: Document Creation and Approval80811. Identify need for new document or revision822. Assign document number per numbering convention:83 - Format: `[TYPE]-[AREA]-[SEQUENCE]-[REV]`84 - Example: `SOP-02-001-01`853. Draft document using approved template864. Route for review to subject matter experts875. Collect and address review comments886. Obtain required approvals based on document type897. Update Document Master List908. **Validation:** Document numbered correctly; all reviewers signed; Master List updated9192### Document Numbering Convention9394| Prefix | Document Type | Approval Authority |95|--------|---------------|-------------------|96| QM | Quality Manual | Management Rep + CEO |97| POL | Policy | Department Head + QA |98| SOP | Procedure | Process Owner + QA |99| WI | Work Instruction | Supervisor + QA |100| TF | Template/Form | Process Owner |101| SPEC | Specification | Engineering + QA |102103### Area Codes104105| Code | Area | Examples |106|------|------|----------|107| 01 | Quality Management | Quality Manual, policy |108| 02 | Document Control | This procedure |109| 03 | Training | Competency procedures |110| 04 | Design | Design control |111| 05 | Purchasing | Supplier management |112| 06 | Production | Manufacturing |113| 07 | Quality Control | Inspection, testing |114| 08 | CAPA | Corrective actions |115116### Document Change Control117118| Change Type | Approval Level | Examples |119|-------------|----------------|----------|120| Administrative | Document Control | Typos, formatting |121| Minor | Process Owner + QA | Clarifications |122| Major | Full review cycle | Process changes |123| Emergency | Expedited + retrospective | Safety issues |124125### Document Review Schedule126127| Document Type | Review Period | Trigger for Unscheduled Review |128|---------------|---------------|-------------------------------|129| Quality Manual | Annual | Organizational change |130| Procedures | Annual | Audit finding, regulation change |131| Work Instructions | 2 years | Process change |132| Forms | 2 years | User feedback |133134---135136## Internal Audit Workflow137138Plan and execute internal audits per ISO 13485 Clause 8.2.4.139140### Workflow: Annual Audit Program1411421. Identify processes and areas requiring audit coverage1432. Assess risk factors for audit frequency:144 - Previous audit findings145 - Regulatory changes146 - Process changes147 - Complaint trends1483. Assign qualified auditors (independent of area audited)1494. Develop annual audit schedule1505. Obtain management approval1516. Communicate schedule to process owners1527. Track completion and reschedule as needed1538. **Validation:** All processes covered; auditors qualified and independent; schedule approved154155> Use the Audit Program Template in [qms-process-templates.md](references/qms-process-templates.md) to schedule audits by clause and quarter across processes such as Document Control (4.2.3/4.2.4), Management Review (5.6), Design Control (7.3), Production (7.5), and CAPA (8.5.2/8.5.3).156157### Workflow: Individual Audit Execution1581591. Prepare audit plan with scope, criteria, and schedule1602. Notify auditee minimum 1 week prior1613. Review procedures and previous audit results1624. Prepare audit checklist1635. Conduct opening meeting1646. Collect evidence through:165 - Document review166 - Record sampling167 - Process observation168 - Personnel interviews1697. Classify findings:170 - Major NC: Absence or breakdown of system171 - Minor NC: Single lapse or deviation172 - Observation: Risk of future NC1738. Conduct closing meeting1749. Issue audit report within 5 business days17510. **Validation:** All checklist items addressed; findings supported by evidence; report distributed176177### Auditor Qualification Requirements178179| Criterion | Requirement |180|-----------|-------------|181| Training | ISO 13485 awareness + auditor training |182| Experience | Minimum 1 audit as observer |183| Independence | Not auditing own work area |184| Competence | Understanding of audited process |185186### Finding Classification Guide187188| Classification | Criteria | Response Time |189|----------------|----------|---------------|190| Major NC | System absence, total breakdown, regulatory violation | 30 days for CAPA |191| Minor NC | Single instance, partial compliance | 60 days for CAPA |192| Observation | Potential risk, improvement opportunity | Track in next audit |193194---195196## Process Validation Workflow197198Validate special processes per ISO 13485 Clause 7.5.6.199200### Workflow: Process Validation Protocol2012021. Identify processes requiring validation:203 - Output cannot be verified by inspection204 - Deficiencies appear only in use205 - Sterilization, welding, sealing, software2062. Form validation team with subject matter experts2073. Write validation protocol including:208 - Process description and parameters209 - Equipment and materials210 - Acceptance criteria211 - Statistical approach2124. Execute IQ: verify equipment installed correctly and document specifications2135. Execute OQ: test parameter ranges and verify process control2146. Execute PQ: run production conditions and verify output meets requirements2157. Write validation report with conclusions2168. **Validation:** IQ/OQ/PQ complete; acceptance criteria met; validation report approved217218### Validation Documentation Requirements219220| Phase | Content | Evidence |221|-------|---------|----------|222| Protocol | Objectives, methods, criteria | Approved protocol |223| IQ | Equipment verification | Installation records |224| OQ | Parameter verification | Test results |225| PQ | Performance verification | Production data |226| Report | Summary, conclusions | Approval signatures |227228### Revalidation Triggers229230| Trigger | Action Required |231|---------|-----------------|232| Equipment change | Assess impact, revalidate affected phases |233| Parameter change | OQ and PQ minimum |234| Material change | Assess impact, PQ minimum |235| Process failure | Full revalidation |236| Periodic | Per validation schedule (typically 3 years) |237238### Special Process Examples239240| Process | Validation Standard | Critical Parameters |241|---------|--------------------|--------------------|242| EO Sterilization | ISO 11135 | Temperature, humidity, EO concentration, time |243| Steam Sterilization | ISO 17665 | Temperature, pressure, time |244| Radiation Sterilization | ISO 11137 | Dose, dose uniformity |245| Sealing | Internal | Temperature, pressure, dwell time |246| Welding | ISO 11607 | Heat, pressure, speed |247248---249250## Supplier Qualification Workflow251252Evaluate and approve suppliers per ISO 13485 Clause 7.4.253254### Workflow: New Supplier Qualification2552561. Identify supplier category:257 - Category A: Critical (affects safety/performance)258 - Category B: Major (affects quality)259 - Category C: Minor (indirect impact)2602. Request supplier information:261 - Quality certifications262 - Product specifications263 - Quality history2643. Evaluate supplier based on:265 - Quality system (ISO certification)266 - Technical capability267 - Quality history268 - Financial stability2694. For Category A suppliers:270 - Conduct on-site audit271 - Require quality agreement2725. Calculate qualification score2736. Make approval decision:274 - >80: Approved275 - 60-80: Conditional approval276 - <60: Not approved2777. Add to Approved Supplier List2788. **Validation:** Evaluation criteria scored; qualification records complete; supplier categorized279280### Supplier Evaluation Criteria281282| Criterion | Weight | Scoring |283|-----------|--------|---------|284| Quality System | 30% | ISO 13485=30, ISO 9001=20, Documented=10, None=0 |285| Quality History | 25% | Reject rate: <1%=25, 1-3%=15, >3%=0 |286| Delivery | 20% | On-time: >95%=20, 90-95%=10, <90%=0 |287| Technical Capability | 15% | Exceeds=15, Meets=10, Marginal=5 |288| Financial Stability | 10% | Strong=10, Adequate=5, Questionable=0 |289290### Supplier Category Requirements291292| Category | Qualification | Monitoring | Agreement |293|----------|---------------|------------|-----------|294| A - Critical | On-site audit | Annual review | Quality agreement |295| B - Major | Questionnaire | Semi-annual review | Quality requirements |296| C - Minor | Assessment | Issue-based | Standard terms |297298### Supplier Performance Metrics299300| Metric | Target | Calculation |301|--------|--------|-------------|302| Accept Rate | >98% | (Accepted lots / Total lots) × 100 |303| On-Time Delivery | >95% | (On-time / Total orders) × 100 |304| Response Time | <5 days | Average days to resolve issues |305| Documentation | 100% | (Complete CoCs / Required CoCs) × 100 |306307---308309## QMS Process Reference310311For detailed requirements and audit questions for each ISO 13485:2016 clause, see [iso13485-clause-requirements.md](references/iso13485-clause-requirements.md).312313### Management Review Required Inputs (Clause 5.6.2)314315| Input | Source | Prepared By |316|-------|--------|-------------|317| Audit results | Internal and external audits | QA Manager |318| Customer feedback | Complaints, surveys | Customer Quality |319| Process performance | Process metrics | Process Owners |320| Product conformity | Inspection data, NCs | QC Manager |321| CAPA status | CAPA system | CAPA Officer |322| Previous actions | Prior review records | QMR |323| Changes affecting QMS | Regulatory, organizational | RA Manager |324| Recommendations | All sources | All Managers |325326### Record Retention Requirements327328> **⚠️ STATUS — QMSR transition (effective 2026-02-02):** FDA's Quality Management System Regulation (QMSR) final rule (89 FR 7496) amended 21 CFR Part 820 to **incorporate ISO 13485:2016 by reference** and removed the legacy QSR subsection structure. The section numbers below (820.30/.181/.184/.198) **no longer exist in the CFR** — they are retained only as a familiar index. The current authority for record retention is **ISO 13485:2016 §4.2.5** (retain "for at least the lifetime of the medical device as defined by the organization, but not less than two years"), with records additions in retained **21 CFR 820.35**. Cite the ISO 13485 clauses — not the 820.x numbers — in current compliance documentation.329330| Record Type | Minimum Retention | Current authority under QMSR (legacy QSR shown for index) |331|-------------|-------------------|------------------|332| Device Master Record | Life of device + 2 years | ISO 13485 §4.2.3 (medical device file)/§4.2.5 (legacy QSR 820.181, historical) |333| Device History Record | Life of device + 2 years | ISO 13485 §4.2.5 + 21 CFR 820.35 (legacy QSR 820.184, historical) |334| Design History File | Life of device + 2 years | ISO 13485 §7.3.10/§4.2.5 (legacy QSR 820.30, historical) |335| Complaint Records | Life of device + 2 years | ISO 13485 §8.2.2/§4.2.5 + 21 CFR 820.35(b) (legacy QSR 820.198, historical) |336| Training Records | Employment + 3 years | Best practice |337| Audit Records | 7 years | Best practice |338| CAPA Records | 7 years | Best practice |339| Calibration Records | Equipment life + 2 years | Best practice |340341> **Decision discipline:** This skill's checklists and tools structure QMS conformity assessment — they do not certify ISO 13485 / QMSR compliance. Final compliance determinations and record-retention decisions are yours to make and must be reviewed and signed off by the named QMR; route FDA-specific regulatory-classification questions to Regulatory Affairs and confirm current 21 CFR 820 / ISO 13485:2016 text at fda.gov before relying on any citation here.342343---344345## Decision Frameworks346347### Exclusion Justification (Clause 4.2.2)348349| Clause | Permissible Exclusion | Justification Required |350|--------|----------------------|------------------------|351| 6.4.2 | Contamination control | Product not affected by contamination |352| 7.3 | Design and development | Organization does not design products |353| 7.5.2 | Product cleanliness | No cleanliness requirements |354| 7.5.3 | Installation | No installation activities |355| 7.5.4 | Servicing | No servicing activities |356| 7.5.5 | Sterile products | No sterile products |357358### Nonconformity Disposition Decision Tree359360```361Nonconforming Product Identified362 │363 ▼364 Can it be reworked?365 │366 Yes──┴──No367 │ │368 ▼ ▼369 Is rework Can it be used370 procedure as is?371 available? │372 │ Yes──┴──No373 Yes─┴─No │ │374 │ │ ▼ ▼375 ▼ ▼ Concession Scrap or376 Rework Create approval return to377 per SOP rework needed? supplier378 procedure │379 Yes─┴─No380 │ │381 ▼ ▼382 Customer Use as is383 approval with MRB384 approval385```386387### CAPA Initiation Criteria388389| Source | Automatic CAPA | Evaluate for CAPA |390|--------|----------------|-------------------|391| Customer complaint | Safety-related | All others |392| External audit | Major NC | Minor NC |393| Internal audit | Major NC | Repeat minor NC |394| Product NC | Field failure | Trend exceeds threshold |395| Process deviation | Safety impact | Repeated deviations |396397---398399## Tools and References400401### Scripts402403| Tool | Purpose | Usage |404|------|---------|-------|405| [qms_audit_checklist.py](scripts/qms_audit_checklist.py) | Generate audit checklists by clause or process | `python qms_audit_checklist.py --help` |406407**Audit Checklist Generator Features:**408- Generate clause-specific checklists (e.g., `--clause 7.3`)409- Generate process-based checklists (e.g., `--process design-control`)410- Full system audit checklist (`--audit-type system`)411- Text or JSON output formats412- Interactive mode for guided selection413414### References415416| Document | Content |417|----------|---------|418| [iso13485-clause-requirements.md](references/iso13485-clause-requirements.md) | Detailed requirements for each ISO 13485:2016 clause with audit questions |419| [qms-process-templates.md](references/qms-process-templates.md) | Ready-to-use templates for gap analysis, audit program, document control, CAPA, supplier, training |420421### Quick Reference: Mandatory Documented Procedures422423| Procedure | Clause | Key Elements |424|-----------|--------|--------------|425| Document Control | 4.2.3 | Approval, distribution, obsolete control |426| Record Control | 4.2.4 | Identification, retention, disposal |427| Internal Audit | 8.2.4 | Program, auditor qualification, reporting |428| NC Product Control | 8.3 | Identification, segregation, disposition |429| Corrective Action | 8.5.2 | Root cause, implementation, verification |430| Preventive Action | 8.5.3 | Risk identification, implementation |431432---433434## Related Skills435436| Skill | Integration Point |437|-------|-------------------|438| [quality-manager-qmr](../quality-manager-qmr/) | Management review, quality policy |439| [capa-officer](../capa-officer/) | CAPA system management |440| [qms-audit-expert](../qms-audit-expert/) | Advanced audit techniques |441| [quality-documentation-manager](../quality-documentation-manager/) | DHF, DMR, DHR management |442| [risk-management-specialist](../risk-management-specialist/) | ISO 14971 integration |