ASUS ESC8000 GPU-Serving BIOS Tuning
Applies a 10-setting low-latency profile + verifies a 4-setting passthrough baseline, over Redfish. Validated on ESC8000-E12P (8× RTX PRO 6000 Blackwell, 2× Xeon 6730P, BIOS 0804). Settings are reversible until you reboot; the tool is dry-run by default.
Quick start
export BMC_PASSWORD='...'
# 1. Dry-run: show what would change on the target (no writes)
python3 scripts/tune_gpu_bios.py --target <BMC_IP>
# 2. Stage only (reversible, no reboot) — settings pending until next boot
python3 scripts/tune_gpu_bios.py --target <BMC_IP> --apply
# 3. Stage + reboot + verify active (the full apply)
python3 scripts/tune_gpu_bios.py --target <BMC_IP> --apply --reboot
Two source modes (pick one)
- Profile (default): targets come from
scripts/gpu_serving_profile.json(token strings validated on BIOS 0804 / registryS0317.8.4.0). - Template (most robust): copy the live values from an already-tuned reference server —
immune to BIOS-version token drift:
Preferpython3 scripts/tune_gpu_bios.py --target <new_BMC_IP> --from-host <tuned_BMC_IP> --apply --reboot--from-hostwhen you have a known-good server (e.g. tuning a second box to match the first).
The profile (what & why)
10 tuned + 4 baseline-verified. Full rationale table in REFERENCE.md. Headline: Resize BAR on, EPP/EPB → Performance, Energy-Efficient-Turbo / C1E-promotion off, Workload → I/O-sensitive, Latency-Optimized on, SNC off (1 NUMA/socket), ASPM-IIO off, AC-loss → Power On. Baseline (must already hold): Above-4G on, SR-IOV on, ACS off (fast GPU P2P — flip to on only at VM adoption). VT-d has no BIOS toggle on this platform (always exposed; gate it OS-side).
Workflow checklist
- Confirm firmware parity first — same BIOS version on source & target, else tokens won't match
(use the
asus-esc8000-firmware-upgradeskill). With--from-host, mismatched versions are flagged. - Dry-run; review the diff with the operator.
--apply --reboot. The reboot isGracefulShutdown → poll Off → On(this build has no GracefulRestart). POST takes ~5–6 min (SNC change forces full memory retraining).- Verify prints
VERIFIED N/N active. The post-reboot host shows0/Nmid-POST — that's normal, it resolves when the host republishes its BIOS map.
Gotchas (details in REFERENCE.md)
- PATCH target is
…/Bios/SD, not/Bios/Settings; needsIf-Matchetag (else 428). - PATCH returns 503 ("inventory processing") while the host is mid-boot — wait for it to settle.
- Pace gently / single connection; a freshly-rebooted AMI BMC locks out on rapid auth (
AccessDenied). - This only touches BIOS. The
intel_iommu=on iommu=ptkernel cmdline is a separate OS-side step.