bridge-conflicts
Purpose
Resolve the single-bridge constraint when more than one MCP runtime path is configured against the same Blender instance (or when ports collide). Blender accepts only one MCP bridge session per instance (default port 9876) — so running Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (community mcp-for-blender, renamed from ahujasid/blender-mcp) concurrently, connecting two MCP clients to one Blender instance, colliding on port 9876, or enabling both Path 1 host (a) and host (b) on one session causes inconsistent signals.
This skill diagnoses the conflict, names the cheapest resolution, and hands off to runtime-readiness for re-verification.
This skill is BlendOps-specific, driven by the single-bridge constraint described in docs/runtime-stack-strategy.md.
Quick start
- list every active / configured bridge for the target Blender session
- check for port collision (commonly
localhost:9876)
- identify which path is intended; which is residual
- propose the cheapest disable / port-isolation step
- hand off to
runtime-readiness to re-verify
When to use
runtime-readiness reports inconsistent signals (e.g. host reports connected but tool calls return the wrong tool surface)
- both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (community
mcp-for-blender, renamed from ahujasid/blender-mcp) add-ons are enabled in the same Blender instance
- two MCP clients are pointing at the same Blender instance (e.g. Claude Desktop with Connector + Cursor with manual MCP)
- Path 1 host (a) and host (b) are both active on a single session
- log or port output shows a collision on default port
9876
When not to use
- no readiness signal yet (run runtime-readiness first) → use
../runtime-readiness/SKILL.md (run runtime-readiness first)
- no runtime path has been chosen yet → use
../runtime-path-picker/SKILL.md (route to runtime-path-picker)
- the user wants to switch or set up a path from scratch → use
../runtime-setup/SKILL.md (route to runtime-setup)
- the bridge matrix is clean and only one path is active, but smoke tests still fail → use
../blender-troubleshooting/SKILL.md (route to blender-troubleshooting)
- the user explicitly wants both paths configured for separate Blender instances on different ports (requires explicit port isolation) → use
../runtime-readiness/SKILL.md (requires explicit port isolation)
Trigger phrases
- "tool surface looks wrong"
- "smoke test passed yesterday but recipe fails today"
- "Lab MCP and ahujasid both installed"
- "Claude Desktop and Cursor both pointing at Blender"
- "port 9876 already in use"
- "single-bridge constraint violation"
Prerequisites / readiness
- list of configured MCP servers per client (
mcpServers in client config files and host toggles)
- list of installed and enabled Blender add-ons inside Blender (Official Blender Lab MCP 5.1+ add-on and community
mcp-for-blender, renamed from ahujasid/blender-mcp)
- log or port output if available (checking default port
9876)
- no Blender execution required from this skill
Input schema
Required inputs
- target Blender instance (binary path or running session identifier)
- list of MCP clients and host options currently configured to talk to that Blender instance
- list of Blender-side add-ons currently enabled (Path 1 Official Blender Lab MCP 5.1+ add-on / Path 2 community
mcp-for-blender, renamed from ahujasid/blender-mcp)
Optional inputs
- recent
runtime-readiness report
- recent smoke test record
- port usage output (around default port
9876)
Assumptions to confirm
- the operator can disable residual add-ons, update configs, or change ports manually
- only one bridge session is intended per Blender instance (or explicit port isolation across separate instances)
- truth states are unchanged by diagnosis and downgrade-only (never upgrade):
- Runtime:
Not Run | Attempted | Produced | Verified | Failed
- Artifacts:
Not Run | Not Produced | Produced | Verified | Failed (default Not Produced)
Output schema
Primary output
- conflict diagnosis: which paths/hosts are present, which path is intended, and which bridges are residual
- cheapest resolution step (propose disabling residual add-on, unregistering extra MCP client/host option, or isolating ports)
- post-resolution verification handoff to
runtime-readiness
Secondary output
- per-bridge state matrix
- explicit "do not run X concurrently with Y" reminders
Evidence / caveat output
- runtime status: unchanged by diagnosis (
Not Run | Attempted | Produced | Verified | Failed; downgrade-only, never upgrade)
- artifact status: unchanged by diagnosis (
Not Produced | Produced | Verified | Failed, default Not Produced; downgrade-only, never upgrade)
- explicit note that resolution requires operator action; this skill only diagnoses and plans, and never executes
Required laws
- ../../laws/official-runtime-only.md
- ../../laws/evidence-before-done.md
- ../../laws/no-arbitrary-python-interface.md
- ../../laws/non-blender-user-language.md
Official runtime boundary
This skill never disables add-ons, edits MCP client configs, changes ports, kills processes, or runs Blender. It only diagnoses the conflict, proposes the cheapest resolution for the operator to perform, and hands off to runtime-readiness.
Operating procedure
- Build the bridge state matrix:
- For each MCP client and host option (e.g. Path 1 host (a) Anthropic Connector, Path 1 host (b) manual MCP, Cursor, Claude Code, etc.), record whether it is registered for the target Blender instance.
- For the Blender side, record whether Path 1 (Official Blender Lab MCP 5.1+) add-on is enabled and whether Path 2 (community
mcp-for-blender, renamed from ahujasid/blender-mcp) add-on is enabled.
- Record configured ports (default port
9876) if known.
- Identify the intended path from the user, brief,
runtime-path-picker, or runtime-readiness.
- Identify residual / unintended bridges:
- Both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (
mcp-for-blender) add-ons enabled -> conflict.
- Two MCP clients pointing at the same Blender instance -> conflict.
- Port collision on default port
9876 (or another shared port) -> conflict.
- Path 1 host (a) and host (b) both enabled on one session -> conflict.
- Propose the cheapest fix for the operator:
- If only Path 1 (Official Blender Lab MCP 5.1+) is intended: propose disabling the Path 2 (
mcp-for-blender) add-on in Blender, removing the Path 2 server entry from the MCP client config, and restarting the client.
- If only Path 2 (
mcp-for-blender, renamed from ahujasid/blender-mcp) is intended: propose disabling the Official Blender Lab MCP 5.1+ add-on in Blender, disabling Path 1 host (a)/(b) entries, and restarting the client.
- If Path 1 host (a) and host (b) are both active: propose disabling one host option so only one remains active for the session.
- If both paths are wanted across separate Blender instances: propose explicit port isolation, separate Blender processes, and separate client configs.
- State explicit
do-not reminders for the operator.
- Hand off to
runtime-readiness to re-verify that only the single intended bridge is active.
Decision tree
- Both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (
mcp-for-blender) add-ons enabled -> confirm intended path (or route to runtime-path-picker if undecided); propose disabling the residual add-on and server entry.
- Two MCP clients configured for the same Blender instance -> confirm which client is the working session; propose unregistering the other client for this instance.
- Two bridges colliding on
localhost:9876 -> propose moving one server to a different port and updating its client config to match.
- Path 1 host (a) + Path 1 host (b) both enabled on one session -> propose keeping only one Path 1 host option per session.
- User wants to switch paths or perform a fresh path setup -> route to
runtime-setup.
- Matrix is completely clean (single bridge, no port or host conflict) but smoke tests still fail -> route to
blender-troubleshooting.
Playbooks
- Playbook A: "Path 1 + Path 2 both installed" — disable the unintended path's Blender-side add-on first, then unregister its MCP server.
- Playbook B: "Two MCP clients" — pick one client per Blender session; unregister the other from this Blender (its config can stay for other Blender instances).
- Playbook C: "Port collision" — change one server's port; update that client's config to match.
- Playbook D: "Path 1 host (a) Anthropic Connector + Path 1 host (b) manual MCP both ON" — pick one host per session per
docs/runtime-stack-strategy.md.
Mode handling
Text-only mode
- diagnosis only, no execution
- runtime status unchanged
- artifact status unchanged
Runtime-ready mode
- diagnose + propose + hand off; this skill never executes the resolution
Blocked runtime mode
- still useful: even when blocked, the conflict can be diagnosed from configs
- mark resolution proposal as text-only
Validation checklist
Pass / Warn / Fail rubric
| Category |
Pass |
Warn |
Fail |
| State matrix |
Complete |
Partial with note |
Missing |
| Intended path |
Explicit |
Inferred without confirmation |
Not identified |
| Residual identified |
Named with reason |
Named without reason |
Not named |
| Port check |
Done or marked unknown |
Done partially |
Skipped |
| Resolution proposal |
Cheapest step + rationale |
Step without rationale |
None |
| Execution claim |
None |
None |
Claimed disabled / changed config from this skill |
Failure handling
- Operator cannot access Blender's add-on list: ask them to inspect Blender Preferences -> Add-ons; meanwhile mark Blender-side state
Unknown.
- Operator cannot access MCP client configs: ask for the client config contents; meanwhile mark client-side state
Unknown.
- Operator is unsure which runtime path should be used: route to
runtime-path-picker to select the path (or runtime-setup if setting up a new path), then verify via runtime-readiness.
Troubleshooting
- If the matrix indicates only Path 1 (Official Blender Lab MCP 5.1+) is active but
runtime-readiness still reports inconsistent signals or a mismatched tool surface -> re-check hidden client configs and port 9876 bindings, then hand off to runtime-readiness to re-verify.
- If the matrix is confirmed clean (single bridge, single client/host, no port collision) but smoke tests still fail -> route to
blender-troubleshooting.
Best practices
- Diagnose the complete bridge matrix before proposing a fix.
- Include explicit
do-not reminders to prevent re-introducing residual bridges.
- Always hand off to
runtime-readiness for re-verification; never claim a resolution was executed or verified by this skill.
Good examples
- "Bridge matrix: Path 1 (Official Blender Lab MCP 5.1+) add-on enabled in Blender, Path 2 (
mcp-for-blender, renamed from ahujasid/blender-mcp) add-on also enabled in Blender; Claude Desktop has Path 1 host (a) Anthropic Connector ON and Path 1/Path 2 manual mcpServers.blender configured on port 9876. Conflict: both Path 1 and Path 2 add-ons enabled + two host configs targeting one Blender instance. Intended path (per runtime-path-picker): Path 1 host (a). Cheapest fix: disable the mcp-for-blender add-on inside Blender, remove the manual mcpServers.blender entry, and restart Claude Desktop. Do-not: enable both Path 1 and Path 2 add-ons or both host (a) and (b) on the same Blender session. Truth states: Runtime and Artifact status unchanged (default Artifact status Not Produced). Handoff: runtime-readiness."
Bad examples
- "Both look configured, just try restarting" (no matrix, no intended path, no resolution rationale, no do-not reminder, no handoff).
User-facing response template
- Bridge state matrix (markdown table)
- Intended path (explicit)
- Conflicts found
- Cheapest resolution step
- Do-not reminders
- Handoff:
runtime-readiness
Anti-patterns
- proposing a fix without building the matrix
- executing the fix from this skill
- ignoring port collisions
- treating Anthropic Connector and manual MCP as if they were independent paths (they are both Path 1 host options; pick one)
Cross-skill handoff
- [upstream_reference] When runtime-readiness reports inconsistent signals →
../runtime-readiness/SKILL.md
- [fallback] If the bridge matrix is clean but failures persist →
../blender-troubleshooting/SKILL.md
- [upstream_reference] If the user wants to change paths or set up a path →
../runtime-setup/SKILL.md
- [upstream_reference] If the intended runtime path has not been chosen yet →
../runtime-path-picker/SKILL.md
Non-goals
- Disabling add-ons, editing MCP client configs, changing ports, killing processes, or running Blender
- Upgrading Runtime or Artifact truth states
- Replacing
runtime-readiness, runtime-path-picker, runtime-setup, or blender-troubleshooting
References
- BlendOps doc: ../../docs/runtime-stack-strategy.md (Single-bridge constraint)
- BlendOps doc: ../../docs/external-runtime-setup.md
- BlendOps doc: ../../docs/unofficial-runtime-bridges.md
- Skill system: ../../docs/skill-system.md
1---2name: bridge-conflicts3description: Diagnose MCP bridge conflicts (Path 1 Official Blender Lab MCP 5.1+ vs Path 2 mcp-for-blender, port 9876 collisions, host mismatch) and hand off to runtime-readiness.4metadata:5 source: https://skillmd.com/skills/thanhnguyxnorg/bridge-conflicts6---78# bridge-conflicts910## Purpose1112Resolve the single-bridge constraint when more than one MCP runtime path is configured against the same Blender instance (or when ports collide). Blender accepts only one MCP bridge session per instance (default port 9876) — so running Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (community `mcp-for-blender`, renamed from `ahujasid/blender-mcp`) concurrently, connecting two MCP clients to one Blender instance, colliding on port 9876, or enabling both Path 1 host (a) and host (b) on one session causes inconsistent signals.1314This skill diagnoses the conflict, names the cheapest resolution, and hands off to `runtime-readiness` for re-verification.1516This skill is BlendOps-specific, driven by the single-bridge constraint described in `docs/runtime-stack-strategy.md`.1718## Quick start1920- list every active / configured bridge for the target Blender session21- check for port collision (commonly `localhost:9876`)22- identify which path is intended; which is residual23- propose the cheapest disable / port-isolation step24- hand off to `runtime-readiness` to re-verify2526## When to use2728- `runtime-readiness` reports inconsistent signals (e.g. host reports connected but tool calls return the wrong tool surface)29- both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (community `mcp-for-blender`, renamed from `ahujasid/blender-mcp`) add-ons are enabled in the same Blender instance30- two MCP clients are pointing at the same Blender instance (e.g. Claude Desktop with Connector + Cursor with manual MCP)31- Path 1 host (a) and host (b) are both active on a single session32- log or port output shows a collision on default port `9876`3334## When not to use35<!-- blendops:generated:start exclusions -->36- no readiness signal yet (run runtime-readiness first) → use `../runtime-readiness/SKILL.md` (run runtime-readiness first)37- no runtime path has been chosen yet → use `../runtime-path-picker/SKILL.md` (route to runtime-path-picker)38- the user wants to switch or set up a path from scratch → use `../runtime-setup/SKILL.md` (route to runtime-setup)39- the bridge matrix is clean and only one path is active, but smoke tests still fail → use `../blender-troubleshooting/SKILL.md` (route to blender-troubleshooting)40- the user explicitly wants both paths configured for separate Blender instances on different ports (requires explicit port isolation) → use `../runtime-readiness/SKILL.md` (requires explicit port isolation)41<!-- blendops:generated:end exclusions -->4243## Trigger phrases44<!-- blendops:generated:start triggers -->45- "tool surface looks wrong"46- "smoke test passed yesterday but recipe fails today"47- "Lab MCP and ahujasid both installed"48- "Claude Desktop and Cursor both pointing at Blender"49- "port 9876 already in use"50- "single-bridge constraint violation"51<!-- blendops:generated:end triggers -->5253## Prerequisites / readiness5455- list of configured MCP servers per client (`mcpServers` in client config files and host toggles)56- list of installed and enabled Blender add-ons inside Blender (Official Blender Lab MCP 5.1+ add-on and community `mcp-for-blender`, renamed from `ahujasid/blender-mcp`)57- log or port output if available (checking default port `9876`)58- no Blender execution required from this skill5960## Input schema6162### Required inputs6364- target Blender instance (binary path or running session identifier)65- list of MCP clients and host options currently configured to talk to that Blender instance66- list of Blender-side add-ons currently enabled (Path 1 Official Blender Lab MCP 5.1+ add-on / Path 2 community `mcp-for-blender`, renamed from `ahujasid/blender-mcp`)6768### Optional inputs6970- recent `runtime-readiness` report71- recent smoke test record72- port usage output (around default port `9876`)7374### Assumptions to confirm7576- the operator can disable residual add-ons, update configs, or change ports manually77- only one bridge session is intended per Blender instance (or explicit port isolation across separate instances)78- truth states are unchanged by diagnosis and downgrade-only (never upgrade):79 - Runtime: `Not Run | Attempted | Produced | Verified | Failed`80 - Artifacts: `Not Run | Not Produced | Produced | Verified | Failed` (default `Not Produced`)8182## Output schema8384### Primary output8586- conflict diagnosis: which paths/hosts are present, which path is intended, and which bridges are residual87- cheapest resolution step (propose disabling residual add-on, unregistering extra MCP client/host option, or isolating ports)88- post-resolution verification handoff to `runtime-readiness`8990### Secondary output9192- per-bridge state matrix93- explicit "do not run X concurrently with Y" reminders9495### Evidence / caveat output9697- runtime status: unchanged by diagnosis (`Not Run | Attempted | Produced | Verified | Failed`; downgrade-only, never upgrade)98- artifact status: unchanged by diagnosis (`Not Produced | Produced | Verified | Failed`, default `Not Produced`; downgrade-only, never upgrade)99- explicit note that resolution requires operator action; this skill only diagnoses and plans, and never executes100101## Required laws102103- ../../laws/official-runtime-only.md104- ../../laws/evidence-before-done.md105- ../../laws/no-arbitrary-python-interface.md106- ../../laws/non-blender-user-language.md107108## Official runtime boundary109110This skill never disables add-ons, edits MCP client configs, changes ports, kills processes, or runs Blender. It only diagnoses the conflict, proposes the cheapest resolution for the operator to perform, and hands off to `runtime-readiness`.111112## Operating procedure1131141. Build the bridge state matrix:115 - For each MCP client and host option (e.g. Path 1 host (a) Anthropic Connector, Path 1 host (b) manual MCP, Cursor, Claude Code, etc.), record whether it is registered for the target Blender instance.116 - For the Blender side, record whether Path 1 (Official Blender Lab MCP 5.1+) add-on is enabled and whether Path 2 (community `mcp-for-blender`, renamed from `ahujasid/blender-mcp`) add-on is enabled.117 - Record configured ports (default port `9876`) if known.1182. Identify the intended path from the user, brief, `runtime-path-picker`, or `runtime-readiness`.1193. Identify residual / unintended bridges:120 - Both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (`mcp-for-blender`) add-ons enabled -> conflict.121 - Two MCP clients pointing at the same Blender instance -> conflict.122 - Port collision on default port `9876` (or another shared port) -> conflict.123 - Path 1 host (a) and host (b) both enabled on one session -> conflict.1244. Propose the cheapest fix for the operator:125 - If only Path 1 (Official Blender Lab MCP 5.1+) is intended: propose disabling the Path 2 (`mcp-for-blender`) add-on in Blender, removing the Path 2 server entry from the MCP client config, and restarting the client.126 - If only Path 2 (`mcp-for-blender`, renamed from `ahujasid/blender-mcp`) is intended: propose disabling the Official Blender Lab MCP 5.1+ add-on in Blender, disabling Path 1 host (a)/(b) entries, and restarting the client.127 - If Path 1 host (a) and host (b) are both active: propose disabling one host option so only one remains active for the session.128 - If both paths are wanted across separate Blender instances: propose explicit port isolation, separate Blender processes, and separate client configs.1295. State explicit `do-not` reminders for the operator.1306. Hand off to `runtime-readiness` to re-verify that only the single intended bridge is active.131132## Decision tree133134- Both Path 1 (Official Blender Lab MCP 5.1+) and Path 2 (`mcp-for-blender`) add-ons enabled -> confirm intended path (or route to `runtime-path-picker` if undecided); propose disabling the residual add-on and server entry.135- Two MCP clients configured for the same Blender instance -> confirm which client is the working session; propose unregistering the other client for this instance.136- Two bridges colliding on `localhost:9876` -> propose moving one server to a different port and updating its client config to match.137- Path 1 host (a) + Path 1 host (b) both enabled on one session -> propose keeping only one Path 1 host option per session.138- User wants to switch paths or perform a fresh path setup -> route to `runtime-setup`.139- Matrix is completely clean (single bridge, no port or host conflict) but smoke tests still fail -> route to `blender-troubleshooting`.140141## Playbooks142143- Playbook A: "Path 1 + Path 2 both installed" — disable the unintended path's Blender-side add-on first, then unregister its MCP server.144- Playbook B: "Two MCP clients" — pick one client per Blender session; unregister the other from this Blender (its config can stay for other Blender instances).145- Playbook C: "Port collision" — change one server's port; update that client's config to match.146- Playbook D: "Path 1 host (a) Anthropic Connector + Path 1 host (b) manual MCP both ON" — pick one host per session per `docs/runtime-stack-strategy.md`.147148## Mode handling149150### Text-only mode151152- diagnosis only, no execution153- runtime status unchanged154- artifact status unchanged155156### Runtime-ready mode157158- diagnose + propose + hand off; this skill never executes the resolution159160### Blocked runtime mode161162- still useful: even when blocked, the conflict can be diagnosed from configs163- mark resolution proposal as text-only164165## Validation checklist166167- [ ] bridge state matrix built (all clients/hosts + both Blender-side add-ons)168- [ ] intended path identified explicitly169- [ ] residual / unintended bridges named170- [ ] port collisions checked around default port `9876` (or marked unknown if no log access)171- [ ] cheapest resolution proposed172- [ ] explicit "do-not" reminders provided for the operator173- [ ] truth states kept unchanged (downgrade-only rule respected; default artifact state `Not Produced`)174- [ ] no execution claimed by this skill175- [ ] handoff to `runtime-readiness` named176177## Pass / Warn / Fail rubric178179| Category | Pass | Warn | Fail |180|---|---|---|---|181| State matrix | Complete | Partial with note | Missing |182| Intended path | Explicit | Inferred without confirmation | Not identified |183| Residual identified | Named with reason | Named without reason | Not named |184| Port check | Done or marked unknown | Done partially | Skipped |185| Resolution proposal | Cheapest step + rationale | Step without rationale | None |186| Execution claim | None | None | Claimed disabled / changed config from this skill |187188## Failure handling189190- Operator cannot access Blender's add-on list: ask them to inspect Blender Preferences -> Add-ons; meanwhile mark Blender-side state `Unknown`.191- Operator cannot access MCP client configs: ask for the client config contents; meanwhile mark client-side state `Unknown`.192- Operator is unsure which runtime path should be used: route to `runtime-path-picker` to select the path (or `runtime-setup` if setting up a new path), then verify via `runtime-readiness`.193194## Troubleshooting195196- If the matrix indicates only Path 1 (Official Blender Lab MCP 5.1+) is active but `runtime-readiness` still reports inconsistent signals or a mismatched tool surface -> re-check hidden client configs and port `9876` bindings, then hand off to `runtime-readiness` to re-verify.197- If the matrix is confirmed clean (single bridge, single client/host, no port collision) but smoke tests still fail -> route to `blender-troubleshooting`.198199## Best practices200201- Diagnose the complete bridge matrix before proposing a fix.202- Include explicit `do-not` reminders to prevent re-introducing residual bridges.203- Always hand off to `runtime-readiness` for re-verification; never claim a resolution was executed or verified by this skill.204205## Good examples206207- "Bridge matrix: Path 1 (Official Blender Lab MCP 5.1+) add-on enabled in Blender, Path 2 (`mcp-for-blender`, renamed from `ahujasid/blender-mcp`) add-on also enabled in Blender; Claude Desktop has Path 1 host (a) Anthropic Connector ON and Path 1/Path 2 manual `mcpServers.blender` configured on port 9876. Conflict: both Path 1 and Path 2 add-ons enabled + two host configs targeting one Blender instance. Intended path (per `runtime-path-picker`): Path 1 host (a). Cheapest fix: disable the `mcp-for-blender` add-on inside Blender, remove the manual `mcpServers.blender` entry, and restart Claude Desktop. Do-not: enable both Path 1 and Path 2 add-ons or both host (a) and (b) on the same Blender session. Truth states: Runtime and Artifact status unchanged (default Artifact status `Not Produced`). Handoff: `runtime-readiness`."208209## Bad examples210211- "Both look configured, just try restarting" (no matrix, no intended path, no resolution rationale, no do-not reminder, no handoff).212213## User-facing response template214215- Bridge state matrix (markdown table)216- Intended path (explicit)217- Conflicts found218- Cheapest resolution step219- Do-not reminders220- Handoff: `runtime-readiness`221222## Anti-patterns223224- proposing a fix without building the matrix225- executing the fix from this skill226- ignoring port collisions227- treating Anthropic Connector and manual MCP as if they were independent paths (they are both Path 1 host options; pick one)228229## Cross-skill handoff230<!-- blendops:generated:start handoffs -->231- [upstream_reference] When runtime-readiness reports inconsistent signals → `../runtime-readiness/SKILL.md`232- [fallback] If the bridge matrix is clean but failures persist → `../blender-troubleshooting/SKILL.md`233- [upstream_reference] If the user wants to change paths or set up a path → `../runtime-setup/SKILL.md`234- [upstream_reference] If the intended runtime path has not been chosen yet → `../runtime-path-picker/SKILL.md`235<!-- blendops:generated:end handoffs -->236237## Non-goals238239- Disabling add-ons, editing MCP client configs, changing ports, killing processes, or running Blender240- Upgrading Runtime or Artifact truth states241- Replacing `runtime-readiness`, `runtime-path-picker`, `runtime-setup`, or `blender-troubleshooting`242243## References244245- BlendOps doc: ../../docs/runtime-stack-strategy.md (Single-bridge constraint)246- BlendOps doc: ../../docs/external-runtime-setup.md247- BlendOps doc: ../../docs/unofficial-runtime-bridges.md248- Skill system: ../../docs/skill-system.md