Completion Design Reviewer
What this skill does
Analyzes completion design documents, frac stage sheets, and pump schedules to validate design consistency, flag deviations from engineering intent, compare against offset wells, and summarize stimulation parameters. Covers plug-and-perf completions, sliding sleeve systems, and multi-lateral configurations.
When to use
- User uploads completion design spreadsheets, frac programs, or pump schedules
- User wants to review or QC a completion design before execution
- User asks to summarize frac parameters for a well or pad
- User needs to compare completion design against offset performance
- User is conducting a post-frac analysis against the design
Trigger phrases
- "Review this completion design"
- "Check the frac stage parameters"
- "Summarize the pump schedule for this well"
- "Does this completion design match the offset wells?"
- "QC the perforation intervals on this stage sheet"
- "Compare planned vs. actual frac parameters"
- "Analyze proppant loading and fluid design for this pad"
- "Flag any completion design inconsistencies"
Inputs
- Completion design spreadsheets (XLSX, CSV)
- Frac stage sheets (PDF, XLSX)
- Pump schedule files
- Perforation design documents
- Optional: offset completion summary for benchmarking
- Optional: casing/tubing design for compatibility check
Outputs
- Stage-by-stage parameter table
- Design summary statistics (totals, averages, min/max per parameter)
- Inconsistency flags (stage spacing outliers, cluster count mismatches)
- Deviation warnings (parameters outside design tolerance)
- Offset comparison table if reference data provided
- Post-frac vs. design comparison if actual data provided
- Structured JSON output with source references
Parameters extracted and validated
Stage design
| Parameter |
Expected range |
Flag condition |
| Stage count |
1–100 stages |
Flag if total < 5 or > 80 for typical laterals |
| Stage length (ft) |
150–400 ft |
Flag if < 100 ft or > 500 ft |
| Cluster count per stage |
3–6 clusters |
Flag if < 2 or > 8 |
| Cluster spacing (ft) |
25–75 ft |
Flag if < 15 ft or > 100 ft |
| Perforation interval (ft) |
1–3 ft |
Flag if > 5 ft per cluster |
Fluid design
| Parameter |
Notes |
| Fluid type |
Slickwater, hybrid, crosslinked, foam |
| Fluid volume per stage (bbls) |
Flag if < 500 or > 5,000 for typical lateral |
| Total fluid volume (bbls) |
Sum across all stages |
| Fluid rate (bpm) |
Flag if > 150 bpm (pump limitation) |
| Acid pre-pad volume (gals) |
For carbonate stimulation |
Proppant design
| Parameter |
Notes |
| Proppant type |
100 mesh, 40/70, 30/50, resin-coated, ceramic |
| Proppant concentration (PPA) |
Flag if > 4 PPA max for slickwater |
| Proppant per stage (lbs) |
Typical: 200,000–2,000,000 lbs |
| Total proppant (lbs) |
Sum across all stages |
| Proppant loading (lbs/ft) |
Typical range: 500–3,000 lbs/ft of lateral |
Pressure and rate
| Parameter |
Notes |
| ISIP (psi) |
Flag if varies > 20% across stages |
| Breakdown pressure (psi) |
Flag if > max allowable treating pressure |
| Max treating pressure (psi) |
Flag if approaching wellbore limits |
| Pump rate schedule |
Validate ramp-up and ramp-down steps |
Mechanical design
| Parameter |
Notes |
| Plug type and depth |
Per-stage plug setting depths |
| Plug to perf spacing (ft) |
Flag if < 50 ft (close-approach risk) |
| Perforation gun specs |
OD compatibility with casing |
| Liner or casing OD |
Check gun/plug OD compatibility |
Validation rules
- Stage spacing consistency: Flag stages where spacing deviates > 25% from median
- Cluster count consistency: Flag stages with cluster count different from design
- Fluid volume ramp: Expected gradual increase toe-to-heel for toe-biased design
- Pressure limits: Max treating pressure must not exceed casing burst / 1.25
- ISIP trend: Should be relatively consistent (+/- 15%) without outliers unless geological reason
- Proppant concentration: Slurry concentration must not exceed pump limits
- Total volume check: Sum of per-stage volumes must equal total volume within 2%
- Plug depth sequence: Plugs must be in ascending depth order (heel to toe)
- Perf cluster count vs. design: Actual cluster count must match design count
- Missing stages: Gap detection if stage numbering is non-sequential
Output schema
{
"design_summary": {
"well_name": "string",
"total_stages": 0,
"total_fluid_bbls": 0.0,
"total_proppant_lbs": 0.0,
"avg_fluid_per_stage_bbls": 0.0,
"avg_proppant_per_stage_lbs": 0.0,
"avg_stage_length_ft": 0.0,
"avg_cluster_spacing_ft": 0.0,
"proppant_loading_lbs_ft": 0.0
},
"stages": [
{
"stage_number": 0,
"top_md_ft": 0.0,
"base_md_ft": 0.0,
"stage_length_ft": 0.0,
"cluster_count": 0,
"fluid_volume_bbls": 0.0,
"proppant_lbs": 0.0,
"max_rate_bpm": 0.0,
"isip_psi": 0.0,
"plug_depth_ft": 0.0
}
],
"validation_results": [
{
"check": "string",
"status": "pass | warn | fail",
"detail": "string",
"affected_stages": [0]
}
],
"offset_comparison": {
"offset_well": "string",
"this_well_proppant_lbs_ft": 0.0,
"offset_proppant_lbs_ft": 0.0,
"this_well_fluid_bbls_stage": 0.0,
"offset_fluid_bbls_stage": 0.0
},
"quality_flags": ["string"]
}
Example response
COMPLETION DESIGN REVIEW — Eagle Ford A12H
══════════════════════════════════════════
Total stages: 32
Total fluid: 72,000 bbls (avg 2,250 bbls/stage)
Total proppant: 38.4 MM lbs (1,200 lbs/ft lateral)
Avg cluster spacing: 45 ft | Avg stage length: 200 ft
VALIDATION RESULTS
───────────────────
✓ Stage spacing consistent (median 200 ft, all within 10%)
✓ Cluster count consistent (4 per stage, all 32 stages)
✓ Proppant concentration within limits (max 2.5 PPA)
⚠ Stages 1–3 (toe): fluid volume 18% below pad average — verify toe-bias intent
⚠ Stage 18: ISIP 5,840 psi vs. avg 6,850 psi — potential natural fracture intersection
✗ Stage 27: plug depth 11,421 ft overlaps perf interval 11,380–11,440 ft — REVIEW REQUIRED
OFFSET COMPARISON (vs. 3 offset wells)
──────────────────────────────────────
Proppant loading: 1,200 lbs/ft (offset avg: 1,050 lbs/ft) +14%
Fluid per stage: 2,250 bbls (offset avg: 2,100 bbls) +7%
Stage count: 32 (offset avg: 29) +10%
1---2name: completion-design-reviewer3description: Completion Design Reviewer4---5# Completion Design Reviewer67## What this skill does89Analyzes completion design documents, frac stage sheets, and pump schedules to validate design consistency, flag deviations from engineering intent, compare against offset wells, and summarize stimulation parameters. Covers plug-and-perf completions, sliding sleeve systems, and multi-lateral configurations.1011## When to use1213- User uploads completion design spreadsheets, frac programs, or pump schedules14- User wants to review or QC a completion design before execution15- User asks to summarize frac parameters for a well or pad16- User needs to compare completion design against offset performance17- User is conducting a post-frac analysis against the design1819## Trigger phrases2021- "Review this completion design"22- "Check the frac stage parameters"23- "Summarize the pump schedule for this well"24- "Does this completion design match the offset wells?"25- "QC the perforation intervals on this stage sheet"26- "Compare planned vs. actual frac parameters"27- "Analyze proppant loading and fluid design for this pad"28- "Flag any completion design inconsistencies"2930## Inputs3132- Completion design spreadsheets (XLSX, CSV)33- Frac stage sheets (PDF, XLSX)34- Pump schedule files35- Perforation design documents36- Optional: offset completion summary for benchmarking37- Optional: casing/tubing design for compatibility check3839## Outputs4041- Stage-by-stage parameter table42- Design summary statistics (totals, averages, min/max per parameter)43- Inconsistency flags (stage spacing outliers, cluster count mismatches)44- Deviation warnings (parameters outside design tolerance)45- Offset comparison table if reference data provided46- Post-frac vs. design comparison if actual data provided47- Structured JSON output with source references4849## Parameters extracted and validated5051### Stage design52| Parameter | Expected range | Flag condition |53|---|---|---|54| Stage count | 1–100 stages | Flag if total < 5 or > 80 for typical laterals |55| Stage length (ft) | 150–400 ft | Flag if < 100 ft or > 500 ft |56| Cluster count per stage | 3–6 clusters | Flag if < 2 or > 8 |57| Cluster spacing (ft) | 25–75 ft | Flag if < 15 ft or > 100 ft |58| Perforation interval (ft) | 1–3 ft | Flag if > 5 ft per cluster |5960### Fluid design61| Parameter | Notes |62|---|---|63| Fluid type | Slickwater, hybrid, crosslinked, foam |64| Fluid volume per stage (bbls) | Flag if < 500 or > 5,000 for typical lateral |65| Total fluid volume (bbls) | Sum across all stages |66| Fluid rate (bpm) | Flag if > 150 bpm (pump limitation) |67| Acid pre-pad volume (gals) | For carbonate stimulation |6869### Proppant design70| Parameter | Notes |71|---|---|72| Proppant type | 100 mesh, 40/70, 30/50, resin-coated, ceramic |73| Proppant concentration (PPA) | Flag if > 4 PPA max for slickwater |74| Proppant per stage (lbs) | Typical: 200,000–2,000,000 lbs |75| Total proppant (lbs) | Sum across all stages |76| Proppant loading (lbs/ft) | Typical range: 500–3,000 lbs/ft of lateral |7778### Pressure and rate79| Parameter | Notes |80|---|---|81| ISIP (psi) | Flag if varies > 20% across stages |82| Breakdown pressure (psi) | Flag if > max allowable treating pressure |83| Max treating pressure (psi) | Flag if approaching wellbore limits |84| Pump rate schedule | Validate ramp-up and ramp-down steps |8586### Mechanical design87| Parameter | Notes |88|---|---|89| Plug type and depth | Per-stage plug setting depths |90| Plug to perf spacing (ft) | Flag if < 50 ft (close-approach risk) |91| Perforation gun specs | OD compatibility with casing |92| Liner or casing OD | Check gun/plug OD compatibility |9394## Validation rules95961. **Stage spacing consistency**: Flag stages where spacing deviates > 25% from median972. **Cluster count consistency**: Flag stages with cluster count different from design983. **Fluid volume ramp**: Expected gradual increase toe-to-heel for toe-biased design994. **Pressure limits**: Max treating pressure must not exceed casing burst / 1.251005. **ISIP trend**: Should be relatively consistent (+/- 15%) without outliers unless geological reason1016. **Proppant concentration**: Slurry concentration must not exceed pump limits1027. **Total volume check**: Sum of per-stage volumes must equal total volume within 2%1038. **Plug depth sequence**: Plugs must be in ascending depth order (heel to toe)1049. **Perf cluster count vs. design**: Actual cluster count must match design count10510. **Missing stages**: Gap detection if stage numbering is non-sequential106107## Output schema108109```json110{111 "design_summary": {112 "well_name": "string",113 "total_stages": 0,114 "total_fluid_bbls": 0.0,115 "total_proppant_lbs": 0.0,116 "avg_fluid_per_stage_bbls": 0.0,117 "avg_proppant_per_stage_lbs": 0.0,118 "avg_stage_length_ft": 0.0,119 "avg_cluster_spacing_ft": 0.0,120 "proppant_loading_lbs_ft": 0.0121 },122 "stages": [123 {124 "stage_number": 0,125 "top_md_ft": 0.0,126 "base_md_ft": 0.0,127 "stage_length_ft": 0.0,128 "cluster_count": 0,129 "fluid_volume_bbls": 0.0,130 "proppant_lbs": 0.0,131 "max_rate_bpm": 0.0,132 "isip_psi": 0.0,133 "plug_depth_ft": 0.0134 }135 ],136 "validation_results": [137 {138 "check": "string",139 "status": "pass | warn | fail",140 "detail": "string",141 "affected_stages": [0]142 }143 ],144 "offset_comparison": {145 "offset_well": "string",146 "this_well_proppant_lbs_ft": 0.0,147 "offset_proppant_lbs_ft": 0.0,148 "this_well_fluid_bbls_stage": 0.0,149 "offset_fluid_bbls_stage": 0.0150 },151 "quality_flags": ["string"]152}153```154155## Example response156157```158COMPLETION DESIGN REVIEW — Eagle Ford A12H159══════════════════════════════════════════160Total stages: 32161Total fluid: 72,000 bbls (avg 2,250 bbls/stage)162Total proppant: 38.4 MM lbs (1,200 lbs/ft lateral)163Avg cluster spacing: 45 ft | Avg stage length: 200 ft164165VALIDATION RESULTS166───────────────────167✓ Stage spacing consistent (median 200 ft, all within 10%)168✓ Cluster count consistent (4 per stage, all 32 stages)169✓ Proppant concentration within limits (max 2.5 PPA)170⚠ Stages 1–3 (toe): fluid volume 18% below pad average — verify toe-bias intent171⚠ Stage 18: ISIP 5,840 psi vs. avg 6,850 psi — potential natural fracture intersection172✗ Stage 27: plug depth 11,421 ft overlaps perf interval 11,380–11,440 ft — REVIEW REQUIRED173174OFFSET COMPARISON (vs. 3 offset wells)175──────────────────────────────────────176Proppant loading: 1,200 lbs/ft (offset avg: 1,050 lbs/ft) +14%177Fluid per stage: 2,250 bbls (offset avg: 2,100 bbls) +7%178Stage count: 32 (offset avg: 29) +10%179```